• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

AC Option?

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
Interesting bit of kit. A buddy recommended I look into this (he has one on their boat). In the past, I had thought about looking into the 12v AC used on Prius, etc but this is plug-n-play almost and has FAR more BTU. The price is comparable to what some of the less-rip surplus sellers are asking for the complete kits (which they picked up for a couple hundred back in the "day").

My buddy's boat is freezing inside in the summer, so I know it can do it's thing, but I want to look into any downside/cons.

Pros:

Multiple BTU output sizes
12v and 24v options
New w/warranty
More modern design and components
Very simple install
Very compact (10"x10" box)
No compressor mounting bracket costs or hassles
No pullies or belts to fuss with
Fewer tidbits needed like suction tubes, parking brake valve, etc
Both cab and habitat applications

Cons (so far):

Needs hoses
36 or 45 amp draw (depending on unit)

stores.12voltairconditioning.com/ves-24l-24-volt-dc-3-piece-mini-split-system-10k-freon-lines-are-not-included/
 
Last edited:

Ronmar

Well-known member
3,184
6,477
113
Location
Port angeles wa
Interesting bit of kit. A buddy recommended I look into this (he has one on their boat). In the past, I had thought about looking into the 12v AC used on Prius, etc but this is plug-n-play almost and has FAR more BTU. The price is comparable to what some of the less-rip surplus sellers are asking for the complete kits (which they picked up for a couple hundred back in the "day").

My buddy's boat is freezing inside in the summer, so I know it can do it's thing, but I want to look into any downside/cons.

Pros:

New w/warranty
More modern design and components
Very simple install
Very compact (10"x10" box)
Both cab and habitat applications

stores.12voltairconditioning.com/ves-24l-24-volt-dc-3-piece-mini-split-system-10k-freon-lines-are-not-included/
“Power consumption 45 nominal amps @24 Volt DC”

That is pretty much all your available 24V alternator output, and at 10,000 BTU output would be running 100% of the time to try and keep up with the heat load...

You could do something like this, with greater output, without risking your alternator...

 

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
“Power consumption 45 nominal amps @24 Volt DC”

That is pretty much all your available 24V alternator output, and at 10,000 BTU output would be running 100% of the time to try and keep up with the heat load...

You could do something like this, with greater output, without risking your alternator...

True for most with the OEM alt. My A1R has a 260v alt, though. I think I could pull it off for the cab AC.

Thanks to that link !
 

Ronmar

Well-known member
3,184
6,477
113
Location
Port angeles wa
True for most with the OEM alt. My A1R has a 260v alt, though. I think I could pull it off for the cab AC.

Thanks to that link !
Yep, that is the alt EVERY LMTV should have:) 45A is not a problem for that alt...

if you have the generation capacity to support it, for less cost and easier install, you could use a Dometic commercial unit(15,000 BTU) on the roof and add an inverter to power it. This would have the added benefit of making AC power available on the truck. This would remove the plumbing requirements, and if you put the inverter near the batteries, the need to string long heavy DC cable to the compressor on the DC powered unit. This unit probably pulls 1600W or about 65A @ 24V. You would probably need a 3KW inverter to feed it properly...

 

simp5782

Feo, Fuerte y Formal
Supporting Vendor
12,088
9,247
113
Location
Mason, TN
They have fluid powered units that have their own compressor run off transmission fluid pressure. These are done by visionaire in Dallas.

Booyco makes a 30,000btu unit that pop up on surplus often. This is just the evaporator unit and blower 3 speed setting but needs it's own thermostat control.

You can make it so its 6 speed. 3 speeds on 12v and 3 speeds on 24v. My 915 cab was 58 degrees with it being 109 outside in California. You can ask @fuzzytoaster how nice it is. It's got a coil bigger than what's on my house.

The engine brackets from the MTVR kits go over to the C7 and 3126 easy enough
 

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
if you have the generation capacity to support it...
Diesel gen (10hp Dewey Battery Charging Auxiliary Power Unit with a 6kW gen head swap) will do it. I just don't want to have to run the gen while driving (I'm already lucky to get 7mpg). Haven't totally ruled out rooftop for the cab, but I sort of have other plans for up there.

:)
 

Attachments

simp5782

Feo, Fuerte y Formal
Supporting Vendor
12,088
9,247
113
Location
Mason, TN
Diesel gen (10hp Dewey Battery Charging Auxiliary Power Unit with a 6kW gen head swap) will do it. I just don't want to have to run the gen while driving (I'm already lucky to get 7mpg). Haven't totally ruled out rooftop for the cab, but I sort of have other plans for up there.

:)
Hydraulic powered Generator/welder. 6kw 36amp per 110 outlet. 50amp 220 plug. They go up go 20kw units
 

Attachments

coachgeo

Well-known member
4,929
3,314
113
Location
North of Cincy OH
“Power consumption 45 nominal amps @24 Volt DC”

That is pretty much all your available 24V alternator output, and at 10,000 BTU output would be running 100% of the time to try and keep up with the heat load...

You could do something like this, with greater output, without risking your alternator...

supplement with Solar. hottest days is bound to have lot of possible solar. So once house batteries charged.... aim all solar to the truck batts to relieve stress on the alt.
 

Ronmar

Well-known member
3,184
6,477
113
Location
Port angeles wa
Diesel gen (10hp Dewey Battery Charging Auxiliary Power Unit with a 6kW gen head swap) will do it. I just don't want to have to run the gen while driving (I'm already lucky to get 7mpg). Haven't totally ruled out rooftop for the cab, but I sort of have other plans for up there.

:)
Well you wouldn’t need the gen, the DC load for the dometic would be around 65A @24v, which your larger alt could support...
 

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
They have fluid powered units that have their own compressor run off transmission fluid pressure. These are done by visionaire in Dallas.

Booyco makes a 30,000btu unit that pop up on surplus often. This is just the evaporator unit and blower 3 speed setting but needs it's own thermostat control.

You can make it so its 6 speed. 3 speeds on 12v and 3 speeds on 24v. My 915 cab was 58 degrees with it being 109 outside in California. You can ask @fuzzytoaster how nice it is. It's got a coil bigger than what's on my house.

The engine brackets from the MTVR kits go over to the C7 and 3126 easy enough
That Visionaire sounds sort of like the system Seal Filner (the "Able" channel on YouTube) ran hooked up to his hydraulic system. He grenaded his power steering pump when he was testing the compressor. I think his was from a crane or forklift. It's an interesting alternative, though.
 

simp5782

Feo, Fuerte y Formal
Supporting Vendor
12,088
9,247
113
Location
Mason, TN
That Visionaire sounds sort of like the system Seal Filner (the "Able" channel on YouTube) ran hooked up to his hydraulic system. He grenaded his power steering pump when he was testing the compressor. I think his was from a crane or forklift. It's an interesting alternative, though.
This runs off transmission fluid much like the PTO units do to spin it. Same things are used on ambulances.
 

coachgeo

Well-known member
4,929
3,314
113
Location
North of Cincy OH
one thing to consider after insulate, insulate, insulate..... is to not be so concerned with cooling the cab space...... but the occupants. A cooled poncho via a small 24v liquid chiller or even a fish tank chiller and inverter could do it likely. Chill vest, shirt or suit.... heck even a chilled hat.... much of the human "radiator" is in the head... cool the head and the cooled blood circulates

I got some supplies for adding this... but it is way down the list. Heck finding a new mechanic is taking a year.. (Might found one finally... will see)
 
Last edited:

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
Well you wouldn’t need the gen, the DC load for the dometic would be around 65A @24v, which your larger alt could support...

So that total is $1312 for the 13500 BTU Dometic (add $70 for the 15000 BTU, but I suspect 13500 would be more than ample for the cab).

AC amazon.com/gp/product/B00VZ547UI/
Gasket amazon.com/gp/product/B000EDUTNQ/
Controls amazon.com/gp/product/B00HJQ86UO/
Inverter amazon.com/gp/product/B07JQKQQTP/

That's pretty reasonable, but again it's draw is a bit much for the older OEM alternators. Viable for my rig, though. I'll have to run the dimensions to see if I can incorporate that into my rooftop plan.

Edit: forgot to include Inverter link
Edit 2: Price was incorrect (invert was in cart twice)
 
Last edited:

Ronmar

Well-known member
3,184
6,477
113
Location
Port angeles wa
So that total is $1750 for the 13500 BTU Dometic (add $70 for the 15000 BTU, but I suspect 13500 would be more than ample for the cab).

AC amazon.com/gp/product/B00VZ547UI/
Gasket amazon.com/gp/product/B000EDUTNQ/
Controls amazon.com/gp/product/B00HJQ86UO/

That's pretty reasonable, but again it's draw is a bit much for the older OEM alternators. Viable for my rig, though. I'll have to run the dimensions to see if I can incorporate that into my rooftop plan.
You will also need an inverter large enough to deal with it’s startup load, but that shouldn’t be too bad. There was a guy on here a while back selling a rig with an older dometic on the roof powered by inverter.
 

coachgeo

Well-known member
4,929
3,314
113
Location
North of Cincy OH
You will also need an inverter large enough to deal with it’s startup load, but that shouldn’t be too bad. There was a guy on here a while back selling a rig with an older dometic on the roof powered by inverter.
was just reading where an rv-er added a soft start to his RV AC and it changed the heavy amp draw start from 40 amp to 17amp. Usually it is the start of the compressor that is huge... after that amps drop back a lot. Half as much ???
 
Last edited:

Third From Texas

Well-known member
2,700
6,312
113
Location
Corpus Christi Texas
You will also need an inverter large enough to deal with it’s startup load, but that shouldn’t be too bad. There was a guy on here a while back selling a rig with an older dometic on the roof powered by inverter.

LOL, I forgot the link. It's factored into the price I posted. And it was in my cart twice, so the first price I posted was way over.

/fixed
 
Last edited:
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock