I moved my battery box forward to make room for a storage box and need to double check my air hose set up. Solvents wrecked my markings to reconnect the lines
Thank you in advance !!!
Thank you in advance !!!
Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Your wet tank appears to be plumbed correctly. I don’t think most are as even the diagrams in the manual show it incorrectly.Hope this helps!
Let me know if I have only bad angles.
Always amazed at how much you know about these trucks.Your wet tank appears to be plumbed correctly. I don’t think most are as even the diagrams in the manual show it incorrectly.
100 of the air from the dryer should pass THRU the wet tank on it’s way to the service tanks. The way the manual shows, the line from the dryer T’s into the rear most port where the outlet to the service tanks are connected. Plumbed that way only maybe 1/4 of the service air ever sees the wet tank...
It looks like your dryer outlet is plumbed to the forward port on the wet tank and the outlet to service is on the opposite port as it should be. I was going to suggest to Reworked that this would be a good time to fix it. If he follows your pics, he will
Thank you!Hope this helps!
Let me know if I have only bad angles.
6x6Thank you!
If you would not mind, If you could drop back so that the three tanks are in view on the horizontal plane (hope that makes sense) , that would be awesome! Is yours a 4x4 or 6x6? Guess I should have asked that first
now that is some complicated stuff right thereHope this helps!
Let me know if I have only bad angles.
A shot of the wet tank would be great! Not a good angle on the one from Ronmar.6x6
I can try to get some when I get back to it.
Sent from my iPhone using Tapatalk
Roger that!Actually I have a better one from when I was explaining to someone else how to re-plumb it...
View attachment 831574
If the line with the protector on is from the dryer, then yes it is correct. your right, it doesn’t matter wich is inlet or outlet, you just don’t want them connected to the same port like in your A0 pic...I just had a chance to look at the two images I posted.
I'm not sure if the A1R (green) is incorrect or not. The tank doesn't care which hole is the inlet and I'm wondering if mine is correct, just installed in opposite ports from the image Ronmar posted.
Of course, I have one spare 1/4" line. And I need to confirm that this is the line from the dryer.
LOL
View attachment 831909
I just had a chance to look at the two images I posted.
I'm not sure if the A1R (green) is incorrect or not. The tank doesn't care which hole is the inlet and I'm wondering if mine is correct, just installed in opposite ports from the image Ronmar posted.
Of course, I have one spare 1/4" line. And I need to confirm that this is the line from the dryer.
LOL
View attachment 831909
CTIS is also fed from the protection valve...I assume the hose on the left is the CTIS supply. Color me curious where your small question-marked line goes. Let us know if you trace it out.
The cab suspension, fan supply tubes are that size but they should be connected to the pressure protection valve.
A1R: The Vast MysteryI assume the hose on the left is the CTIS supply. Color me curious where your small question-marked line goes. Let us know if you trace it out.
The cab suspension, fan supply tubes are that size but they should be connected to the pressure protection valve.
We get it, advertisements are annoying!
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!