- 1,026
- 1,475
- 113
- Location
- Wilson County, Texas
Aftermarket replacement for the fan clutch solenoid that tends to go bad & start to stick and/or leak & can't be found at a reasonable price to replace.
Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
It doesn't sound like it is the solenoid, it sounds like you have some sort of short or ground issue somewhere that is causing an overload that's making a breaker trip & causing a full power shut down. It could be 100's of things really. Electrical issues are a pain in the rear, they can take a while to isolate... especially if they don't happen consistently.Hey Colt,
Great video. Thank you.
What were your symptoms that led you to replace this fan solenoid?
FYI - here is a fan clutch solenoid error I am dealing with. What this your problem?
1998 MTV M1083 Fan Clutch Engages and Shuts Down Electronics
Hi Guys, My name is Joel. I have a M1083 with CAT 3116. Was just driving down the highway and said to myself, "this truck runs better and better every time I drive it". I should have kept my mouth shut. It left me on the side of the highway 30 seconds later! I have the following problem...www.steelsoldiers.com
This is exactly what my post & video is about.... this solenoid & I reference this video & Ronmar in the video description. He was the one who shared it with me after I tried 3 other options with failure each time. Very grateful that he found this!and if your fan soleniod is not working and needs to be replaced...they are very difficult to find..MME has crap shoot soleniods for ..wait.. wait.. $300.. but since most of us rather not get hosed by MME , there is an alternative from The Mad LMTV Scientist himself Ronmar...it's 1/10 the cost, quieter and works like a champ
It doesn't sound like it is the solenoid, it sounds like you have some sort of short or ground issue somewhere that is causing an overload that's making a breaker trip & causing a full power shut down. It could be 100's of things really. Electrical issues are a pain in the rear, they can take a while to isolate... especially if they don't happen consistently.
At the end of my video, I do the test to show how the solenoid is supposed to work when it is properly letting air go to the fan clutch & not with the power on & off with the air tanks full. If you are hearing the clutch purge when you get to around 200 deg., it's doing what it should. Your problem is for sure on the electrical side.
Thanks Colt,
Yes, I agree, I don't think it is a solenoid issue either. There is some electrical short. Do you have any suggestions on where to even start to trouble shoot this?
Thanks for your time,
- joel
(775) 223 6633
I don't remember. Looked it up a bunch of times. It's irrelivant because it's a dead end anywways. You can't get that part anymore with exception of a few that Midwest Military Equipment has as old stock for a high price. Possible that some may pop up on eBay in the future, but, no matter what, they will all be old. The new solenoid will be fresh & not have deteriorating rubber in it. Also, is much cheaper.what is the original, NSN?
Ends with -24P if I remember correctly.OK
Which TM is it in?
That most definitely sounds like wiring or a component issue. As Colt mentioned the 200f thermal sw removes power from the circuit to de-energize the coil of the solenoid valve, vent the clutch air and engage the fan.Thank you! This is very good info. But I don't know it addresses my issue(s). My fan solenoid IS working, BUT when temp reaches 200F solenoid opens, fan engages, BUT I get an immediate total electrical shut down in cab. All gauges go dead, power to fuel shut off solenoid is cut, engine stops. I can then cycle the master power switch, OFF, then ON, start the truck as normal. And all is functional UNTIL temp reaches 200F and shut down cycle starts again.
Question:
- Is this a wiring issue(s)
- Or, if the fan clutch solenoid is failing how/why would it cause a total electrical short of the truck
Ideas?
OK reviewing the schematics I think you have 2 things going on:Thank you! This is very good info. But I don't know it addresses my issue(s). My fan solenoid IS working, BUT when temp reaches 200F solenoid opens, fan engages, BUT I get an immediate total electrical shut down in cab. All gauges go dead, power to fuel shut off solenoid is cut, engine stops. I can then cycle the master power switch, OFF, then ON, start the truck as normal. And all is functional UNTIL temp reaches 200F and shut down cycle starts again.
Question:
- Is this a wiring issue(s)
- Or, if the fan clutch solenoid is failing how/why would it cause a total electrical short of the truck
Ideas?
I whole heartedly disagree with Ronmar overly simplistic "diagnosis" .. it's either the Fetzer Valve or Muffler Bearing ..and you'll need a 2 way adjustable tent wrench to fix it....touche' Ronmar... (insert mic drop)OK reviewing the schematics I think you have 2 things going on:
1. The fan control thermal switch is bad and when it is hitting 200F, it is removing power from the solenoid, but at the same time switching it to ground. The fan power is drawn thru CB22, but that gets power from the switched ignition relay, like everything else that uses 24v ignition power.
2. You have a bad connection in the switched ignition circuit, perhaps even the control power relay K2’s contacts… when that fan switch hits 200F and shorts, it adds a load path to ground which due to a bad connection causes the X6 buss(control power relay output) to brown-out. This squashes trans controller, fuel cut solenoid ect and brings things to a screeching halt…
Easy test: Disconnect the thermal switch connector in the upper radiator pipe. Run the engine and use the fording switch in the upper left corner of the inst panel to control the fan. This will probably work OK. Since the only change is the disconnected switch, if it works OK, thats your problem…
Good Luck!
I have the valve but I need one of the muffler bearings. Got a spare one?I whole heartedly disagree with Ronmar... it's either the Fetzer Valve or Muffler Bearing ..and you'll need a 2 way adjustable tent wrench to fix it....touche' Ronmar... (insert mic drop)
MME has them for $700.I have the valve but I need one of the muffler bearings. Got a spare one?
Ronmar!OK reviewing the schematics I think you have 2 things going on:
1. The fan control thermal switch is bad and when it is hitting 200F, it is removing power from the solenoid, but at the same time switching it to ground. The fan power is drawn thru CB22, but that gets power from the switched ignition relay, like everything else that uses 24v ignition power.
2. You have a bad connection in the switched ignition circuit, perhaps even the control power relay K2’s contacts… when that fan switch hits 200F and shorts, it adds a load path to ground which due to a bad connection causes the X6 buss(control power relay output) to brown-out. This squashes trans controller, fuel cut solenoid ect and brings things to a screeching halt…
Easy test: Disconnect the thermal switch connector in the upper radiator pipe. Run the engine and use the fording switch in the upper left corner of the inst panel to control the fan. This will probably work OK. Since the only change is the disconnected switch, if it works OK, thats your problem…
Good Luck!
We get it, advertisements are annoying!
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!