- 2,145
- 3,526
- 113
- Location
- Pepperell, Massachusetts
2.0 V is in spec. Seems the set is flashing which would indicate the MPU is working.
Sounds like the set is trying to flash the head but I'd expect the voltmeter to read closer to 208 volts. Meter may be wonkey.
Check the AC voltage at the convenience outlet with S1 in START and see if you get something close to 120 VAC.
Sounds like the set is trying to flash the head but I'd expect the voltmeter to read closer to 208 volts. Meter may be wonkey.
Check the AC voltage at the convenience outlet with S1 in START and see if you get something close to 120 VAC.