• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

M1088a1 disconnect switch relay problem

Ronmar

Well-known member
3,859
7,498
113
Location
Port angeles wa
Did you ever bypass AND measure voltages? If the disconnect is bypassed, whether it clicks or not makes no difference.

I would bypass the disconnect module, and both the ignition relays at the same time. Things may start clicking but that is just a symptom of voltage loss. Start at the batteries and measure 12 and 24 to ground. Then measure at the disconnect terminal 12 and 24 to ground. Then at the LBCD and power panel. You are looking for where the voltage drops off along the path to the power panel.

With the disconnect and ign relayes jumpered you should have only about half volt drop from the batteries to the ign terminals in the power panel with only the ign on loads applied...
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
Finally had a moment to work on this girl.
I swapped out the LBCD with a borrowed unit and that cured the incessant clicking. Now I have full and steady power to the cab, but the start button had no effect. I raised the cab and jumped the solenoid on the frame and it fired right up. Then I discovered the transmission keypad was not on. I had a borrowed unit on hand so I hooked it up and that worked. I drove it around the lot a few times and everything seems copacetic. I parked it and tried the start button and still no effect at all.
I'm getting a replacement LBCD. I want to test the TCM one more time before calling it.

Will need to look into the start issue now.

Thanks very much for everyone's help. Any guidance on the start problem is much appreciated.
 

Ronmar

Well-known member
3,859
7,498
113
Location
Port angeles wa
What NDT said. The TCU powers K26 when in neutral. K26 powers K11 which provides the power to the starter switches… 15 PSI of oil pressure de-energizes K11 disabling the starter and putting the alternator online… so does taking the trans out of neutral…
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
What NDT said. The TCU powers K26 when in neutral. K26 powers K11 which provides the power to the starter switches… 15 PSI of oil pressure de-energizes K11 disabling the starter and putting the alternator online… so does taking the trans out of neutral…
I recall a reading a post a while back that referenced the lights on the generator, one led above 14v and the other above 28v. With the engine running, both lights are flashing amber, alternating between the two. Please remind me what that signifies.
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
What NDT said. The TCU powers K26 when in neutral. K26 powers K11 which provides the power to the starter switches… 15 PSI of oil pressure de-energizes K11 disabling the starter and putting the alternator online… so does taking the trans out of neutral…
I have power to the TCU, and power to K26, but nothing at K11.
Where do I go from here?
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
K11 is a solenoid on the Power Distribution panel correct? if so.. how are you determining you have no power to K11?- by sound of it not clicking?? or did you measure voltage there?
K11 on this PDP is the ALT EXCITE relay. Pin 30 shows 24v but for some reason it will not supply power to 87.
I jumped pin 30 to 87 and 87a and still no power to Alt Excite.
 

Ronmar

Well-known member
3,859
7,498
113
Location
Port angeles wa
There are 2 parts to the K11 circuit. DC voltage applied by K26 and a path to ground provided by the oil pressure switch.

Do you have an oil pressure idiot light when you turn on the ignition switch? The same path to ground that allows K11 to energize is also provided to the oil light by the low oil pressure switch down by the starter…
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
What is going on with the transmission controller at this point? All lit up and no codes?
Transmission controller light up as it should. Circuit breaker also tests fine.
FYI, I can start the truck by jumping the auxiliary relay on the frame, but not with the start button.
I’m watching the generator now. It flashed alternating amber for several minutes, now is alternating with green at 28v and amber at 12v.
 

abfisher1798

Active member
189
87
28
Location
Blythe, California
I thought this was a starting problem?
It started out as something else. After replacing the LBCD the “clicking” issue went away. I also discovered the TCU was bad and changed that. Now everything powers up as normal but no response from the start button.
I mentioned the generator in case that might be a factor.
 

TomTime

Well-known member
Steel Soldiers Supporter
676
1,664
93
Location
MD.
I had a similar problem with the starting my engine from the starter button in the cab. But, it would start by jumping the relay on the frame by the starter. I had cleaned and checked everything everyone suggested and what it said to check in the TM's. Still no start and no K11 lite.
@Ronmar (big thanks to him!) suggested to check the engine oil switch and I found that was the problem. I took the two pin plug off the oil switch and jumped the two pins and K11 lite up and the engine started from the cab. Bad oil switch.
Not sure that will be your problem, but it may be worth checking.
Tom.
 

Ronmar

Well-known member
3,859
7,498
113
Location
Port angeles wa
As Tomtime mentioned, thats why i asked if you have an oil idiot light. K11 must energize to power the start circuit. But if you jumpered K11 pin 30 to 87 that should have powered the start circuit the same as K11 would… that is of course provided you have a valid circuit. Back to rule one with DC, voltage is not good till measured good under load… With K11 30-87 jumpered, what does the voltage measure at K11 pin 30 when you push the start button?
 
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks