Zeus51
Active member
- 115
- 36
- 28
- Location
- Birmingham, AL
It seems I never have to post anything unless it’s a wiring question. I have had a m1008 for 10 years with no real issues. I have recently acquired a m1009. The previous owner says he converted to 12v but it looks like all he did was disconnect the gen 2 wiring and remove the alt. I have reinstalled a known running gen 2 from a donor m1009 I also have. I traced the wiring to make sure it was solid. I also replaced the gen 1 with a known working gen 1 alternator from my donor. When I disconnect the white clips with the red and brown wires off the alternators, both gen 1 and 2 pass the key on/off test. And both alt’s have the appropriate 12/24v to the post. And the batteries are fully charged reading 12.4v. I have done the Doghead relay and glow plug switch. Since completing all this, the truck would crank and run but the gen 1 light wouldn’t go off and the gen 1 alternator wasn’t charging the front battery. Gen 2 seemed to be working and rear battery was reading 14.6v while running.
Today, I cleaned some terminals and tried to crank it. It wouldn’t crank and the engine grounding strap on the back passenger side of the engine got super hot and started smoking. So I immediately turned it off. before I start purchasing a new grounding strap and troubleshooting blindly, I thought I’d ask opinions on what I should do?
Today, I cleaned some terminals and tried to crank it. It wouldn’t crank and the engine grounding strap on the back passenger side of the engine got super hot and started smoking. So I immediately turned it off. before I start purchasing a new grounding strap and troubleshooting blindly, I thought I’d ask opinions on what I should do?