- 841
- 1,532
- 93
- Location
- Mesa Colorado
I hope this isn't a duplicate problem discussed on another thread. I've searched around and not found much on this particular problem.
Anyway, cold weather starting has been a big problem on my A1. The engine block heater helps but still that air inlet heater pulls 70amps and seems to drag down the voltage and causes the "chargeing system" light to come on after I've gotten the engine running. Usually I can turn off then restart and the system resets. That happens almost every time in cold weather.
Today however, the truck took 15secs to get running and then after about 60secs of running the voltage dropped below 10volts and the whole system went dead and engine stopped, but the starter motor kept spinning (and is still spinning) until I jumped out of the truck and operated the battery disconnect. Now I can't get the engine to crank and The starter motor is spinning and whining full speed whenever I turn the battery switch back on.
The K11 cutout relay is on (green light) when I turn on the ignition and all CBs are reset.
I've read thru the electrical schematics but those are hard to follow since they put a different part of the circuit on so many multiple pages. Not sure why I have a starter motor running on continuously but not the throw-out solenoid.
I'm wondering if I've welded a relay contact closed or something?
The amperage of the starting motor spinning free-wheel And the air inlet heater was 80 amps.
(I'm going to disable that air inlet heater since it pulls so many amps! Hell the Alternator is only rated 100.)
Anyway, cold weather starting has been a big problem on my A1. The engine block heater helps but still that air inlet heater pulls 70amps and seems to drag down the voltage and causes the "chargeing system" light to come on after I've gotten the engine running. Usually I can turn off then restart and the system resets. That happens almost every time in cold weather.
Today however, the truck took 15secs to get running and then after about 60secs of running the voltage dropped below 10volts and the whole system went dead and engine stopped, but the starter motor kept spinning (and is still spinning) until I jumped out of the truck and operated the battery disconnect. Now I can't get the engine to crank and The starter motor is spinning and whining full speed whenever I turn the battery switch back on.
The K11 cutout relay is on (green light) when I turn on the ignition and all CBs are reset.
I've read thru the electrical schematics but those are hard to follow since they put a different part of the circuit on so many multiple pages. Not sure why I have a starter motor running on continuously but not the throw-out solenoid.
I'm wondering if I've welded a relay contact closed or something?
The amperage of the starting motor spinning free-wheel And the air inlet heater was 80 amps.
(I'm going to disable that air inlet heater since it pulls so many amps! Hell the Alternator is only rated 100.)
Attachments
-
183.2 KB Views: 15