I’ve responded to this on FB…this is quite simple to TS, pull the GP lead and run the truck as normal, if you aren’t getting a melted GP?
you now know it’s your EESS box is the issue, IMO it’s the box…your GP timer is stuck on and 24v is present after 9 second.
i suspect all the other GP’s are also bad as well now, looking at the picture tell me that plug experienced longer than 9 seconds of voltage, I see this often…have you yet checked for voltage after 9 seconds and the GP wait lamp expired?
you now know it’s your EESS box is the issue, IMO it’s the box…your GP timer is stuck on and 24v is present after 9 second.
i suspect all the other GP’s are also bad as well now, looking at the picture tell me that plug experienced longer than 9 seconds of voltage, I see this often…have you yet checked for voltage after 9 seconds and the GP wait lamp expired?