• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Recent content by Nowa

  1. N

    3KW MEP-831A won't stop once it runs. Need help.

    So i just remove my diode from k12 and i ran it it work perfectly fine but the diode isnt bad cuz i tested it with another generator
  2. N

    3KW MEP-831A won't stop once it runs. Need help.

    So, It does turn on and run but it wont turn back off when u trun the switch back to off unless u put it back to on and also my k12 and k15 relay lights up but my k14 dont
  3. N

    3KW MEP-831A won't stop once it runs. Need help.

    So i looked at the k12 while running it does illuminate a green light on the left side of the relay but any lights on fault lamps..
  4. N

    3KW MEP-831A won't stop once it runs. Need help.

    Its a. 3kw 60hz Model: MEP-831A Ser no: FZA19318 Thankyou.
  5. N

    3KW MEP-831A won't stop once it runs. Need help.

    It wont stop once it runs, but when i turn the switch from off to on back while running it stops, so what could be problem here?? Need help. Moderators note: Edited title to now include genset model.