    802A & main utility entrance panel ground / neutral bonding question

    It's a kinda hard concept to grasp & I had a rough time with it myself. The gist of it is that while your ground is... grounded... the neutral eventually goes to ground, but it doesn't always just go to ground. Having your neutral & ground tied together in one place is good... but having them...
  2. F

    802A & main utility entrance panel ground / neutral bonding question

    [I'm not an electrician] but I'm pretty OK at it. Step #1 for me would be to ohm out between the two bars. They're separate bars, yes, but they may be interconnected by the panel housing itself. My guess is that you'd find very low/no resistance? (Meaning that there's an insulator or something...
  3. F

    MEP-831A

    There's nothing keeping you from manually setting the throttle on it... since it's an inverter, there's no "60hz" setting like most generators. You will lose all the engine shutdown safeties (low oil pressure, overheat, low fuel) so there's also that.
  4. F

    Mep831a Yanmar engine repurpose

    I've had the same curious thoughts, for the same reason. Passed a snowblower for sale in a driveway the other day, and went hmmmmmm that could be cool.... Aside from the tapered crankshaft, a couple other things to consider. Unless you want to pull start it, I don't believe the flywheel on it...
  5. F

    Mep 831a

    Yeah it was right around there... maybe could have been as high as 7 gallons, my fuel gauge was dead & the fleabay special I bought worked for about an hour & now just reads slam full... so that was pretty much based on me eyeballing the strainer. I've only really run it the one outage, which...
  6. F

    Mep 831a

    As far as fuel consumption, mine was running my house on about 5 gallons per day, give or take. I couldn't tell you what I was drawing (my KW gauge was broken) but I'd guess 10-12ish amps on average. I have a VP race jug with a cap rigged up as an auxiliary tank, and had no problem going 24...
  7. F

    mep-831a how to backfeed to OFF GRID electric panel to charge solar bank or run house

    [Not an actual electrician] If you're off-grid & don't have to worry about a lockout or transfer switch (and I'd presume also not permits) I'd personally say there's no reason not to at least do it as right as using a power inlet, rather than a suicide cord. Especially in this case, there's...
  8. F

    M1102 Trailer: Generator mounts

    Kinda sorta looks like the tower trailer for an FIRRE system maybe? (Just googled 'M1102 surveillance trailer' cuz it looked like maybe mounting for an aerial mast kinda thing)
  9. F

    MEP-802A Fuel System issue.

    Mine vibrated like crazy when I had it on the trailer. Decided to start simple, found some urethane pads from Energy Suspension, 9.9533G... just throwing one under each bolt I'd guess knocked down about 75% of the vibration. If you wanted to get a little fancier, they come in a pack of 8, you...
  10. F

    MEP-804a charred wire. No AC

    The charred wire is almost certainly not the problem, it's a symptom. Something put too much juice through it, causing it to get overheated. I'd reckon that since the generator has safeguards to prevent overloading (and this wire is in fact part of one of those safeguards) the cause is...
  11. F

    How do you move your generator(s)?

    You don't necessarily have to put your units on pallets to move them with a pallet jack. You could, for example, make 4 blocks of say 3" tall 4x4, drill & countersink a hole in the middle of each block, and bolt one to each of the trailer mounting holes... just enough to get the bottom of the...
  12. F

    How do you move your generator(s)?

    I don't think the rollers at the front of the forks would play well with the rest of the skid that's below the fork slots. We have a straddle pallet stacker at work that'd work pretty well (basically a hand-motivated forklift, with legs that straddle around the skid rather than a counterweight)...
  13. F

    What trailer is this?

    I think he wants to tow the HMMWV with the Unimog, not t'other way 'round.
  14. F

    Acquired Another MEP-802A - A Couple of Questions

    If you put a 1200 watt heater on one leg, and nothing on the other leg, and were running at 120v, you'd see 10A draw on one leg, and 0A on the other. Would your 1200w heater be drawing 1200w, or 2400w?
  15. F

    Can I run 12 volt LED's from a single battery on my MEP802?

    Yes, there are plenty of search results. Problem is, most of them aren't 24V, and they say as much. I wish they had functional filtering, but it seems at odds with letting anyone & their brother hawk Chineseum willy-nilly using imaginary brand names. Edit: I bought some that claimed to be...
  16. F

    Can I run 12 volt LED's from a single battery on my MEP802?

    This, but definitely check. I gad a hard time finding 24v/multi-volt 194 bulbs for gauge backlights. Ended up just buying a bag of them (that claimed 12v) from the 'zon. Thought I was in business, they did light up (very well!) but after about 2 minutes the magic smoke came out.
  17. F

    MEP-802A GP Win

    1-1/4" pipe... not sure if NPT or NPS. You'd think after I left the top cover off for 3 weeks I woulda noticed if it was obviously tapered, but I guess not.
  18. F

    Acquired Another MEP-802A - A Couple of Questions

    For whatever it's worth, I picked up my 1st about a month ago, it's an '11 production unit with 270 hours on it... don't think it was actually issued, and I'm thinking it's probably got PMCS time on it & about nothing else. I haven't even run out what was in the tank when I got it from GP...
  19. F

    Are there any trailers big enough to haul an MRZR that work with a HMMWV?

    DRASH trailer is probably one of your best bets, but I don't know what the inside wheelwell deck width is. The one like aghumvee posted has some really square wheelwells, don't think driving over them would work well. There's also the LTT-FE (which I think is also under some other DRASH/ECU...
  20. F

    M101A2 to 5 Lug?

    I saw some adapters from 6x5.5" googling around. I'm not knowledgeable on 101s, but if they're Dexter brakes & the same setup as the 1101 brakes (the hub pic looks it) they're standard Dexter 12" 7k drums... which are identical to Dexter 5.5k or 6k 12" drums except for the outer bearing, and...
Top