• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. D

    Me 004a transformer went out, then had other troubles.

    [emoji46] found this box with the wires cut and spliced. Would this be the cause with a new transformer box?
  2. D

    Me 004a transformer went out, then had other troubles.

    Swapped out the speed switch nothing different.
  3. D

    Me 004a transformer went out, then had other troubles.

    I got around to changing out the rectifying diodes. After taking them out and testing each I didn't find any that were bad according to a multimeter all had .40 or better reading on them. I started the generator and ZIP on the hertz and volts meters and checked with meter and no power. I then...
  4. D

    Me 004a transformer went out, then had other troubles.

    Correct, should be here Saturday.
  5. D

    Me 004a transformer went out, then had other troubles.

    The rectifier diodes.
  6. D

    Me 004a transformer went out, then had other troubles.

    Thanks for all directing and/or suggestions.
  7. D

    Me 004a transformer went out, then had other troubles.

    Just ordered Diodes, will do.
  8. D

    Me 004a transformer went out, then had other troubles.

    Looking to order diodes. 1N1109, and 1n1109r. Do I order three of each and where is best. If I replace a set ml ight as well replace all.
  9. D

    Me 004a transformer went out, then had other troubles.

    Maybe a minute while warming up. Forgive me for asking... where is the rotating rectifier?
  10. D

    Me 004a transformer went out, then had other troubles.

    I started as usual and noticed the two gauges did not come online. I reved the engine to approximate speed and tried to re-excite. Nothing. I went into the house swapped overrelays. Went back to generator and loaded the generator with load. The needles came up but dropped back out. I re-excite...
  11. D

    Me 004a transformer went out, then had other troubles.

    I didn't hear anything unusual. Even the other person didn't and he works a lot on various equipment. Someone mentioned diodes. Is this something that might go out with the transformer?
  12. D

    Me 004a transformer went out, then had other troubles.

    They vibrate but not jump. The ac voltage fluctuates minimum and the percentage guage fluctuates at about 20 % . Nothing other than that.
  13. D

    Me 004a transformer went out, then had other troubles.

    Had someone do it and there was nothing.
  14. D

    Me 004a transformer went out, then had other troubles.

    Yes I did that several times.
  15. D

    Me 004a transformer went out, then had other troubles.

    I was instructed to use a 9 volt battery on a f1 wire. The two meters jumped when I touched the f1 to the positive side and the other to the neg. Is that flashing the field?
  16. D

    Me 004a transformer went out, then had other troubles.

    My Gen Mep-004a had been running fine for years then one day a puff of smoke out the back. Found out the stator box was bad as the transformer had fried. After replacement of the box, I could not get the hertz and volts needle to rise on the restart after the repair. I got someone to try it on...