  1. B

    Load Bank?

    Can you share part number or link to the hearing elements you use? Do they have thermostats on them? Or do you bypass them?
  2. B

    New mep-803a control panel wiring problem?

    Hi, I got a couple of mep-803a generators from auction. I was looking one of them over in the control box and it looks like someone was previously tracing some wires. Can anyone give me an idea of what they were looking trouble shooting? I’ll post a pic of wires they tagged. I have not started...
  3. B

    MEP-005a First run on Load bank with smoke

    Thanks for comments on the load bank... Im not an electrician, and probably shouldn't be "playing" with generators but I want to get familiar with electricity in general, hopefully i don't get "too" familiar with it :-).. sewerzuk - my phases are too imbalanced and after reading your last post...
  4. B

    MEP-005a First run on Load bank with smoke

    I thought it would be be faster if i swapped out some of the 3,800w heaters with 5,500w heaters. So I changed 4 of them. 5,500w x 4=22,000w and 3,800w x4 = 15,200 for a total of 37,200w. That is more than 110% so I may disconnect one 3,800w heater to get to the 110% (~33,000kw). I replaced 4...
  5. B

    MEP-005a First run on Load bank with smoke

    Amps draw of L1,L2 and L3 all 8 elemets running @ 208v MEP-005a Running 75% Load after 2 hours less exhaust smoke http://youtu.be/58RU3ZlgfJc MEP-005a 75% Load On, then Off, Then back on http://youtu.be/gFrosn-NWTI
  6. B

    MEP-005a First run on Load bank with smoke

    Thanks or all of the great comments, sorry for taking so long to get back on here. 1800 Diesel - I was running straight diesel, so I added 100 gallons worth (whole bottle) of Lucas Diesel fuel system cleaner to a full tank. Harleyd315 – I do have some tar dip marks coming from the...
  7. B

    looking for a mep 005a alternator

    When i got my MEP-005a It had a log book in one of the boxes. There were notes saying that the batteries were changed several times and that the unit did not charge the batteries. I tested it and couldnt get the altenator to charge, So i took it to an altenator shop in town, they told me it was...
  8. B

    MEP-005a First run on Load bank with smoke

    Thank you for all of the great replys. I was going to tinker with the generator today but got called away just after I fired it up. I poured a bottle of some Lucas Diesel fuel cleaner in to the tank, Hopefully tomorrow I will be able to let it run for several hours. sewerzuk, Good eye.... I...
  9. B

    MEP-005a First run on Load bank with smoke

    Hi, I got around to getting a home made load bank setup with some parts that were laying around. I have eight 240v 1ph 3,800watt water heater elements. I have 4 breakers wired to a pair of elements, so one of the legs is a little lighter than the other two. When we ran the engine unloaded it...
  10. B

    Picked up my first Mep-002a

    Do you mean something like this? Reliance 2,000 Watt 120 Volt Electric Water Heater Element | Wayfair
  11. B

    Picked up my first Mep-002a

    I put off the first MEP002 to the side. The second one was more complete. The darn thing wouldn't fire up. i noticed smoke coming out all around the head. No head gasket... I didn't have another gasket so I stole the whole head with gasket off the other generator. It fired right up. Here is a...
  12. B

    Picked up my first Mep-002a

    Hello, This is my first post on this site. Some how I came down with a mild case of MEP disease and had to buy one for a fun project. I also ended up buying a second one that I have not picked up / Received yet. I hope I get well soon. Also I was asked by a member to post lots of pictures so I...