  1. J

    I joined the 803A club as well!

    If the sensed voltage is over a set point the maintainer doesn’t turn on so I do not believe it would cause any harm to remain plugged in while the alternator outputs power
  2. J

    I joined the 803A club as well!

    I believe the alternator puts out 4A and my maintainer puts out 2.5A. I am unsure of the generators DC amp draw while running but I would expect the 2.5A charger to keep it running for a long time if not indefinitely if the alternator fails.
  3. J

    I joined the 803A club as well!

    So, if the alternator fails it will only run for about 10hrs until batteries drain? I should be able to extend that some since my maintainer is always plugged in to shore power.
  4. J

    Connected my MEP-803A the proper way as my home standby generator... Install pics...

    "connected to house electrical system, 4 wires connected from house to generator lugs, bonding strap disconnected. You are using the house electrical panel ground." I believe this is where you have to be careful as some switches disconnect the neutral. It is my understanding that the statement...
  5. J

    Connected my MEP-803A the proper way as my home standby generator... Install pics...

    Each line on the Hz gauge represents 0.5 Hz. Did you think each line was 1 Hz?
  6. J

    Check your power line connections

    I have just three words after seeing that, especially with all the testing you did to locate the problem "check chassis grounds"
  7. J

    MEP-802A and MEP-803A Modifcation

    X2 Noticed that when I installed the battery tender.
  8. J

    2011 Mep 803 wiring for house

    It is my understanding that if the ground path is uninterrupted, as with most interlock setups, then it is properly grounded for powering the house. And, if you wanted to power something remotely that is not on the house circuit then it needs to be wired differently, have the ground rod driven...
  9. J

    2011 Mep 803 wiring for house

    If it is connected to the house panel and grounded there, you do not need or want a second ground by driving a ground rod. The ground rod is for stand alone power generation where the unit is not connected to another ground.
  10. J

    MEP Sizing Help

    Can you repeat that in a different color?
  11. J

    MEP Sizing Help

    I have a Geospring hot water heater and leave it on all the time in heatpump mode. Runs on 500w after the initiation sequence, which fires the 5500w resistance heating elements to verify they are working. It only take a couple minutes to run the sequence, so I turn that breaker on first before...
  12. J

    MEP Sizing Help

    100,000 hours is not equal to 100,000 miles or you are driving really really slow. I went with the 803, because my "smart" hot water heater has a startup sequence that fires the electric elements which requires 5500w. Don't expect to operate much electric heat even with an 803. I heat with...
  13. J

    MEP803 help for a Noob...

    I would put a battery maintainer on it first chance you get, so it is always charged and ready to go. If I didn't have one on mine, I am sure I would have been down the same road already.
  14. J

    Wife is now a green iron believer

    X2, most small tractors today are short stroke high rpm jobs that suck fuel and make power at upper revs. I was thinking PTO generator before buying my 803, but couldn't justify taking a $30k tractor and putting generator hours on it, plus I might need it during a storm. There is a farmer up...
  15. J

    MEP003A Running The House Again

    If the AC is on, why do you need a lengthy pre-heat?
  16. J

    802a, Hertz dropping under load.

    I wan't promoting auto start, that just happened to be part of the technology which allows for remote monitoring. I'm sure there are much more simple device out there that one could connect simply to monitor volts, Hz, etc. remotely via phone instrad of a kill-a-watt meter. I have one meter for...
  17. J

    802a, Hertz dropping under load.

    While on this subject, I would also like to mention that I now use a digital kill-a-watt meter to verify / adjust voltage and Hz at the power unit as well as monitor from inside my house during outages. I do not rely entirely on the control panel mechanical gauges when making adjustments and I...
  18. J

    802a, Hertz dropping under load.

    When I made this mistake, it was the first gauge I recall encountering with .5 increments. Honest mistake when I typically deal with lines meaning 1 or 2. The good thing is that it is a lesson you do not easily forget.
  19. J

    802a, Hertz dropping under load.

    Been there myself
  20. J

    Major Power Outage Mep-002 Getting Workout

    Sounds like my pre-mep days, although last outage my 803 did fail to distribute power until I flipped the AC interrupt toggle several times. I was in panic mode and posted on SS and I was prompted to try the toggle a second time and it worked. I would have given up since I flipped the toggle...