• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. yohanusmarcus

    MEP005A frequency meter not working.

    I thought as much. Am I wrong in seeing the temp sensor bellow the lower radiator hose? There are no other sensors with Canon connectors other than the speed sensor.
  2. yohanusmarcus

    MEP005A frequency meter not working.

    The photo just above the one of J5 two wires taped up. The coolant switch only has one wire on it second photograph.
  3. yohanusmarcus

    MEP005A frequency meter not working.

    Best I can tell the missing part goes to TB101-18 and TB101-18
  4. yohanusmarcus

    MEP005A frequency meter not working.

    Did that still won't stay running
  5. yohanusmarcus

    MEP005A frequency meter not working.

    I have chased the disconnected wires down to the J5 plug pins X and y I think hard to see
  6. yohanusmarcus

    MEP005A frequency meter not working.

    Disconnected oil switch jumped a to d started machine and it still will not stay running. Question is which is the temp switch also something has been removed
  7. yohanusmarcus

    MEP005A frequency meter not working.

    Ok I disconnected the oil sensor
  8. yohanusmarcus

    MEP005A frequency meter not working.

    So regardless of the other tests this definitely needs done right.
  9. yohanusmarcus

    MEP005A frequency meter not working.

    Do I need to leave it connected or test it on the bench
  10. yohanusmarcus

    MEP005A frequency meter not working.

    This is the a5 board itself I'm testing?
  11. yohanusmarcus

    MEP005A frequency meter not working.

    Well I will have to find a 120vdc source for one of the tests. I'll figure something out. Unless that's a typo and it's supposed to be 120vac. Will get the first tests done and get back to you.
  12. yohanusmarcus

    MEP005A frequency meter not working.

    Installed the jumper TB101-1 to TB101-9. Started machine, it stays running without battle short on. What does this tell us and where do we go from here? I also had to pull the DC circuit breaker to turn it off.
  13. yohanusmarcus

    MEP005A frequency meter not working.

    Ok I'll take the relay box back out install the jumper and hook it all back up and let you know what happens
  14. yohanusmarcus

    MEP005A frequency meter not working.

    So when I use the paperclip on s9 is it a to b to c or just a to b
  15. yohanusmarcus

    MEP005A frequency meter not working.

    Ok will do this first thing in the morning.
  16. yohanusmarcus

    MEP005A frequency meter not working.

    Still won't stay running when I install the jumpers I leave the wires connected as well?
  17. yohanusmarcus

    MEP005A frequency meter not working.

    When you press the reset button is it supposed to stay down? It's spring loaded apparently.
  18. yohanusmarcus

    MEP005A frequency meter not working.

    Oh it is safty wired do I need to replace the safty wire and is it timed?
  19. yohanusmarcus

    MEP005A frequency meter not working.

    This is the speedswitch correct? If I disconnect it will the motor start and run