• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. The FLU farm

    FLU419 SEE HMMH HME Owners group

    My guess is brass, like most older radiators.
  2. The FLU farm

    FLU419 SEE HMMH HME Owners group

    I doubt that they are, but I can go scrape some paint off of one tomorrow and find out.
  3. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Solder up the hole and hope there won't be too many other leaks?
  4. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Bring one each of the old ones to NAPA?
  5. The FLU farm

    FLU419 SEE HMMH HME Owners group

    The normal recommended 50/50 mix works great. Just don't put it in a handy old style oil can like I did. It has a crimp on the bottom, which works well with the regular oil it was intended for, but the acetone/ATF mix crept through that crimp. Yes, it's that good of a penetrant.
  6. The FLU farm

    FLU419 SEE HMMH HME Owners group

    I would avoid heating anything and instead put a few drops of acetone/ATF on the threads and let it work - over a few days. My 1-inch hydraulic hydraulic impact , good for about 2,500 ft .-lbs., would likely remove the nuts, but together with the studs. And overall I've had much better...
  7. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    I would think so. Have had vehicles that only revved to under 5,000 and the only filtration they had was a centrifugal filter. In those it was built into the crankshaft pulley.
  8. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    Don't overlook that both batteries should ideally have come off the production line one after the other. In other words, never replace just one in a dual (or more) battery application.
  9. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    Ideally you should charge with only a few amps for a couple of days, then up the amperage. Of course, most smart chargers/maintainers won't activate when the voltage is too low, but can be tricked into charging by hooking up a good battery in parallel for 15-20 minutes.
  10. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Hmm. The compressor is direct driven and always runs when the engine is. Or should. Either way, nothing you did with the wiring could impact the function of the compressor. I'd guess that the compressor does pump air, but it doesn't get to the tanks anymore. Is the regulator flowing air?
  11. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Speaking of LEDs. In the past couple of days I've been working on getting the lighting functional on the FLUs. One had a dim work light, turned out to be resistance in the head/work light switch. But the first one I bought had nothing...other than power to the work lights. Disgusting, really...
  12. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Well, apparently there is. Even Amazon has them, $8.69 for a 10-pack.
  13. The FLU farm

    FLU419 SEE HMMH HME Owners group

    If memory serves me, that bulb was used in typical aftermarket VDO gauges.
  14. The FLU farm

    FLU419 SEE HMMH HME Owners group

    I wouldn't be surprised if you could buy them on Amazon. And speaking of surprised. Today I took another stab at figuring out why the Winter SEE hasn't started for well over a year...as in won't even make a click when hitting the starter button. Had already verified that it most likely was an...
  15. The FLU farm

    Using my SEE for real work

    Haven't used a FLU for real work for a while, which is why I've been quiet. Anyway, those rippers are great, I think. In my case it's when digging horse graves and getting into the river rock. Without, the bucket teeth would just slide off the larger rocks and making me think I'd be better off...
  16. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    Been meaning to find out where/why the pump on the M1008 is leaking (other than because the vent line is plugged) for years. How close to done am I? After all, they say that the first step is to admit that you have a problem. No idea who said that.
  17. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    When first getting the FLU HME it was smoking badly. Did a fair amount of research and settled on Liqui Moly . Not that I can say what actually fixed the problem, but it went away.
  18. The FLU farm

    What have you done to your CUCV today/lately - Part 2

    Retard it a bit?
  19. The FLU farm

    FLU419 SEE HMMH HME Owners group

    Good point. I couldn't resist buying it once I found out about them, basically to complete the collection. There might be another one in Kansas or Missouri, but I haven't been able to verify that. The hydrostatic drive intrigues me and I wish I could hang on to the dozer blade. Used that on a...
  20. The FLU farm

    FLU419 SEE HMMH HME Owners group

    I have considered listing the HME there, if for no other reason because some of the Burning Man crowd might see it. After all, it's one of the few stock vehicles that would look right in place there.
Top