    New Potential Owners - Generator Model Numbers ARE Important!

    I saw that, CRAZY. Some low hour 803a generator plant units (2) for $9,000+
  2. J

    Advice on Overhauling MEP803A engine

    If you have little pitting just hone the cylinders and add new rings. I've honed some deep pitting and had great success. Had a 803a with really bad pitting and sold it to a friend and told them if it failed I would replace the motor. That was 5 years and 8,000 hours ago, still going strong.
  3. J

    Mep 803a rebuild

    Little heat around the flywheel plate and jumping on the bearing always works for me.
  4. J

    Mep 803a rebuild

    Need to take the door that covers the lugs off and the center pillar that door attaches to. Then looking at the back of the head, you will see 4 nuts. Take those off and use a jaw puller to push the stator and stator bearing out while lifting on the engine. The engine will come out with the...
  5. J

    Mep 803a rebuild

    I leave the generator head in place and pull the motor. It's alot easier in my opinon. Need to unbolt the radiator support and take everything off in 1 piece. I just finished pulling the motor out of a 813a to put into an 803a. Took about 3 hours to pull it.
  6. J

    Gen set humor ? because it's so stinking cold.

    Are you sure its oil? Looks like wet stacking coming from the exhaust manifold gasket. Have you been running it with little or no load several hours?
  7. J

    Looking for a MEP803a side panel door

    Yes get Light in the Darks door. I don't have one but I've used Light in the darks several times and they fit perfect!
  8. J

    Looking for a MEP803a side panel door

    Take a pic. I may have it.
  9. J

    What generator is this?

    That is cool. Lister Petter LPW4 motor like the 803a. So I would say a 10kw AC unit.
  10. J

    803A Hard to start

    Hard to say. If some fuel had a lot of water in it, it would cause rust quickly. Mainly clogged due to the manufacture process.
  11. J

    803A Hard to start

    Got around to cutting it open. Looks like it was mainly blocked to manufacture process and then rust closed it the rest of the way. It was between the 2nd and 3rd line.
  12. J

    Removing MEP-802A Crank Pulley

    Left hand threads. Opposite of righty tight.
  13. J

    803A Hard to start

    It was blocked somewhere in the middle of the tube. I could not blow air through the end starting at the return line and could not blow air through the 1st 2 rubber lines closest to the return line.
  14. J

    803A Hard to start

    Still don't know what happen. I'm going to cut the line this weekend, in half to see. I tried to blow 120 psi compressed air in the fitting of the return line and could not get air to bypass. I tried each of the rubber hoses that go to the metering pumps and could only get 2 hoses to blow air...
  15. J

    803A Hard to start

    I wanted to give everyone an update. Jim brought the generator to me to work on and we found that the hard line going to the metering pumps had failed and clogged completely. After replacing with a good used line, the generator performs perfect. Hope this helps someone else.
  16. J

    MEP-002a: Hollingsworth, Libby, Fermont

    I'm over in west Tn and can help you with a 002a. I have 2 in stock but not ready, I need to replace the motor in one (the sheriffs department I got it from pointed the exhaust up and the engine collected water) and then the other is my personal unit that I'm going to have to upgrade to a 003a...
  17. J

    MEP-003A stalling under high load test?

    How did the droop adjustment go? It could be the droop adjustment, droop adjustment spring or injectors.
  18. J

    803A Hard to start

    I think light in the dark gave you my number. If you want me to look at your unit just give me a call. I'm only a couple of hours from you. I've refurbished hundreds of these and can fix it for you.
  19. J

    Mep-802a engine change

    It may smoke some but not a lot and it should not run rough. Are you sure the engine is a reman? Let it run about 10 mins and if its still running rough and smoking, you may have more issues.
  20. J

    Mep-802a engine change

    Looking good, just switch the rotor and flywheel over to the new engine and put it back in reverse.