• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. S

    MEP-803 fuel pump Length discrepancy

    Somebody was messing with the fuel pumps, looks like 1 and 2 had shims added. I went and pulled the injectors and took them apart. 3 out of 4 were pretty rusty inside. Getting to the point where I’m just gonna junk this whole damn thing, who knows what else is wrong with it. so much for the...
  2. S

    MEP-803 fuel pump Length discrepancy

    yes I did, it compresses by hand and fuel comes out. Looking at it more, it seems like there’s too many shims for this pump. I’m gonna take #1 pump off tomorrow and measure those shims. what’s The best way to get the pin aligned on the pump with the fuel rack when putting it back in ? I’m...
  3. S

    MEP-803 fuel pump Length discrepancy

    Hey guys pump number 2 won’t produce any fuel while cranking with the line off. Looking through the engine tm, on 3-23, it says to shim the pump. Never done this before, anybody have any experience with this procedure ? Thanks for any help in advance
  4. S

    MEP 831-A K1 relay won’t engage

    No never seen it work like it should. With a bunch of the cable ties cut, it makes me think that somebody was in here trying to fix it before but gave up.
  5. S

    MEP 831-A K1 relay won’t engage

    Thanks to kloppk, problems been solved. Ended up being a reverse wire on the battle short switch. Flipped both around and K1 works like it should. The S7- 5 and 8 contacts were backwards. Thanks again to kloppk. Guy knows his stuff.
  6. S

    MEP 831-A K1 relay won’t engage

    Also Does the S5 switch close a ground ?
  7. S

    MEP 831-A K1 relay won’t engage

    Hey guys, got a 831-a, and having a problem with the a/c contractor (k1). My problem is basically the switch on the front (S5) won’t engage the relay (k1). I know k1 is good, I pulled it out and energized it with 24 and the relay clicks and has continuity. I pulled out S5 too, tested ok. If I...