No doubt 24V was to be able to charge from the vehicle's alternator, or to jump the vehicle using the house batteries as a spare set, essentially.
A good solar system makes that not needed, HOWEVER.........you have options
Option 1 is to put a small solar panel dedicated for the starter...
You're adding more points of failure.
More switches = more to go wrong.
Also, you need isolate shore power and gen so you're not backfeeding the shore plug...unless you intend to do that...
A simple 4 position (Inverter, generator, shore power, off) would make the most sense, IMO. Those...
There are a couple things that matter but don't matter at the same time.
The best oils available in the 60's are utter #%(& compared to even the crappiest oils today. Modern enhancements in lubricity, additive packages, detergents, surfactants, etc. mean you're already giving it something...
Your 120V generator and 120V shore power should be the same circuits.
You'll have a switch that cuts from shore power to genset when either the gen or shore power is connected.
Don't make things too complicated...
Your 120V side should have a battery charger that charges the 12V side when...
No A/C either?
Ehh... well... Follow https://www.thetruckstop.us/forum/files/nn10.pdf as a start.. You'll obviously have to remove one of the alternators or at the very least remove the belt... The M1010 uses 2 -24V alternators, and not 2 -12V alternators like the other CUCVs, but you already...
So.. after putting in the replacement engine, and putting the front clip back on.. and realizing how simple the wiring harness is..... I ran into an issue.
So, the side markers on the corners (not the park/turn signals up front) run through the major/minor of the parking/turn circuit. The side...
Dead. Didn't even make it out of committee.
WA has been tightening restrictions on military vehicles, even nullifying registrations in some cases.
Because each office is independently run, some things can get through the cracks, but there is a memo telling them to NOT register ANY military...
That Turbo 400 uses the vacuum pressure to determine shift points. The vacuum regulator is there for a reason.
Also, if the vacuum pump is hooked up directly to the modulator, you should get super early shifts.
The lines, if not replaced, are almost 40 years old at this point. Replace the...
There are situations where I use both a star washer and split washer, but never just a split washer. Internal tooth star washers grab, and they're great when you don't have kep nuts and need to tighten something down with minimal access from the other side. The split washer will put tension on...
The plugs are self-limiting. They won't draw more than X amps.... The internal resistance is usually 1-2 Ohms with a nominal resistance of 1.6 Ohms, per TM 9-2320-387-24-1
Using Ohms law... and the rated voltage of the wellman plugs (which I believe is 22v, not 24v, but we'll run with 24v)...