Thanks for the help guys
but I'm still a little thick on why I need to have a ground rod in addition to the genset being grounded to the house service through the ground wire in the 6/4cord.
Ike
It is a excellent switch box but regardless I would never throw the switch while it was live, I've...
OK
One problem at a time
My hubbel line supply is 8ga
Panel wires are 10ga ( yes they should be heavier but have been in use for the last 21 years and look fine ) I've read that a switched neutral is nice to have so as to not have any possible feedback to the pole and zap a...
ok from what your describing then I leave my genset the way it is which ( as I understand it ) is to keep it with the ground/neutral tied together ( bonded ) and not seperate them. Now the ground is unbroken ( no switch ) allthe way into the panel(s) so why would I need to have another ground...
Previous owners put in a sub panel coming off the 400amp breaker box I have. The sub panel runs limited outlets/lights in the house including well pump and hot water heater, it was originally setup for 30amp hubbel I have since put in 50amp hubbel ( and heavier guage supply)
I missed last year but am definetly going this year, I already made res at the local Sleep Inn by the Don Garlits museum ( $65.00 night if you mention "MVPA"). Very good turn out and as mentioned gets bigger each year and its locate on the grounds of a huge covered flea market
Sleep Inn (352)...
OK
I read the posts and the link and I'm even more confused Sooo let me ask this
I have 4 wire (6/4soow) cord running to my house transfer switch which have seperate neutral & ground terminals/lugs ( whatever). Since I have 4 wires with one being ground do I (still ) need to isolate the...
Back out the center bolt that holds the blower to the shaft a few turns so that it not touching the blower then position the tapered puller shaft on the little counter drilled hole on the bolt ( its there for that purpose ) tighten up on the puller jacking bolt and then (as Spedmon said) tap the...
Heres my old/bad (shorted ) stator
Darn thing looked brand new, the ( used) stator I bought to replace it with looked so bad in comparison that when I went to reassemble I grabbed the old one and started putting it back on :doh:
Just in case your second (used) VR is bad too.
I also bought my NOS VR from Eriks Mil Surplus
Voltage Regulator/Rectifier (Battery Charging) For Onan MEP-002A / MEP-003A 5KW and 10KW Generator Sets, FVR4006
Its suppose to be white oak but I have seen quite a few that were red.
I did the troop seat on my old 37 with Epay wood, cheaper and as durable as white and as strong also a very good looking wood to which I could not bring myself to paint it
This is a excellent event
I still make the trip down from Ga to attend
11-12-13 FEB 2011 - The Southern Outpost Military Vehicle Winter Rally and Swap Meet - Sponsored by the First Florida Chapter, MVPA & The Market of Marion - Located 10 Miles South of Ocala, FL. at the Market of Marion...
.010 & .013 are wrong
These were the old settings that the mil superceded in 1951 ( Change order one) to .015 hot for both in /ex
I originally did my ( rebuilt ) 230 at the old settings and always had a flutter on the vac gauge ( thought it was the carb ) that dissappeared when I reset them both...
I've used Delo for years in my diesels ( cummins & Navistar) then recently switched to Rotela, My deuce gets the store brand 15w-40 diesel oil being as little miles as I put on it I'll be changing it do to age and not from milage put on it
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.