Interesting, I would assume this would be with an empty truck, and not one with an extra ton or so of cargo in the bed, even though the initial set-up for the procedure doesn’t stipulate this...:) note the pressure diff between the 1078 and the 1080(cab and chassis only, about 2400# lighter) ...
That is what it sounds like. Did the procedure have you setting it for a particular pressure? unless they have some arbitrary pressure spec in mind, that doesn’t make a lot of sense for setting the proportioning valve. I mean the point of the valve is to byas the brakes for varying weight in...
Yea, the manufacture may have a specified duty cycle, but duty cycles are usually imposed because of an inability to dissipate heat. I would guess if this unit can maintain a steady temp when operating, it probably has no duty cycle...
That doesn’t sound right. I would hope there is no way for combustion gas to enter the airstream. But a fuel leak before the combustion chamber might allow fuel to come in contact with the burn chamber or heat exchanger and get heated enough to generate smoke/vapors which are being drawn into...
Thats a lot of heat! An 8x8x12 structure has 512 sq/ft of surface area. If it had 2“ of insulation it might make R10? At 70F inside and say -20 outside, crunching some numbers with say 24SQ/ft of R2 windows and one air change per hour, that is around 7000 BTU/hr required to maintain 70F...
Good information. The transmission via the neutral start relay provides 24V to the start relay K1 In the PDP. The start button provides a path to ground to energize K1, via the contacts of the starter lockout relay(K24) which disables the starter once the engine has oil pressure. That is the...
One question I didn’t notice in my rapid scan of this old thread, was what EXACTLY is going click when you push the starter button? That will tell y0u a lot about where to look next...
9W-3043 is the cat P/N used in the IT28 tool carrier. It’s 52A@24V and paired with 2 group 31 batteries(100AH/25A acceptance) In series. What batteries are you running? For the 4 battery 6TL config using wet cells 52A would be slightly overloaded trying to meet 60A acceptance charge. With 4...
No it has a low volt cutoff..., but it would be used in conjunction with a charger/maintainer, so I doubt it would ever trip unless one battery gets so bad that it absorbs all the power provided by the charger/within the limits of the equalizer... Now if you are so inattentive as to not catch...
I find it is also good to charge them then give them a good heavy load test(1000A) for a few seconds or so, then recharge them. the two hawkers that came with my truck were in bad shape. After doing this a few times I actually got them to hold a decent charge. The only good thing about the...
I did a few years ago on a charger I had, it did improve some marginal batteries, but they were not horrible... Thats funny I just bought one of those last night, as I needed another automatic charger:)