  1. A

    MEP006A Voltage Conversion

    ok will take a look at those items. thanks again.
  2. A

    MEP-006A Issues

    ok will take a look thank you and I'm just going to replace the whole thing.
  3. A

    MEP-006A Issues

    sorry i guess my question is what is the BIG AUCTION SITE? do you have a link? thank you.
  4. A

    MEP-006A Issues

    I need a voltage regulator for my MEP006a too. You mentioned there is one available on the BIG AUCTION SITE?
  5. A

    MEP006A Voltage Conversion

    Got it switched back to 3 phase 416v thank you for all your help.
  6. A

    Mel-006a

  7. A

    MEP006A Voltage Conversion

  8. A

    MEP006A Voltage Conversion

    The above snapshots are from the TM manual for the MEP006A. The third pic shows the correct configuration for the three phase (at least that's what I think). The rest of the pics is what I used to determine the wiring.
  9. A

    MEP006A Voltage Conversion

  10. A

    MEP006A Voltage Conversion

    yes it seems like a few at least one of the wires is in the wrong place based on what I was able to find form the manual. looks like the wire numbers you referenced above a different for the MEP006A except for the third one. Below is how i think it should be wired. X7E16A connects to TB6-7...
  11. A

    MEP006A Voltage Conversion

    got it thanks.
  12. A

    MEP006A Voltage Conversion

    Ok I'll see if I can figure that out, I suck at reading wiring diagrams :). Also when you say regulator, you referring to the voltage regulator correct? thanks again.
  13. A

    MEP006A Voltage Conversion

    some pics of the back after replacing the cut copper back and removing the jumper
  14. A

    MEP006A Voltage Conversion

    Here is the current configuration of the reconnection board. I suppose I need to shift it up vertically so that the number 4 lines up with the arrow for 240/416 correct?
  15. A

    MEP006A Voltage Conversion

    The generator is overseas in Africa. It's been used in at a bakery. I bought it in Tacoma WA and shipped it to Africa. I have a non-profit I'm running there.
  16. A

    MEP006A Voltage Conversion

    I'm not at the generator currently but I think I see what you are saying now. will have someone at the location take a closer look
  17. A

    MEP006A Voltage Conversion

    yes the jumper is removed. I figured that restores it back to factory setting but I'm still not getting the required voltage. maybe what's missing is moving the reconnection board. Which I'm so sure where exactly to move it to. So just to confirm, I suppose to remove all 12 mounting nuts and...
  18. A

    MEP006A Voltage Conversion

    I have already replaced the cut copper tie bar with continuous one that reconnects T11 and T12
  19. A

    MEP006A Voltage Conversion

    Yes I'm trying to get 3 phase 416 out of it