  1. L

    MEP 803A shorted battery

    I know guyfang will appreciate this 👍
  2. L

    MEP 803A shorted battery

    Funny how symptoms and problems collide. My dad had disconnected the batteries (sparked cable in process), cleaned the terminals on the fuel gauge (primary reason for disconnecting the batteries), and just called to say that after 2 hours, he found that he had hooked the wires up incorrectly...
  3. L

    MEP 803A shorted battery

    He unplugged the fuel pump and it still tripped. Dead crank will turn it over.
  4. L

    MEP 803A shorted battery

    I’ll plow through the TM’s over the weekend, thanks!
  5. L

    MEP 803A shorted battery

    When you turn S6 to prime, CB1 pops out.
  6. L

    MEP 803A shorted battery

    Hi, I’ve searched SS but can’t find the answer. My dad was disconnecting the batteries and the loose terminal flopped and shorted, causing a large spark. He said the relay behind the instrument panel keeps tripping when attempting to start. He installed a new one and same thing. Any pointers...
  7. L

    MEP-803A Battery fitment

    Interstate 51 fits with plenty of wiggle room.
  8. L

    MEP 803A smoke after oil change

    The smoke cleared up after a few starts, so yesterday was moving day (off the trailer to it’s final resting place.
  9. L

    MEP 803A smoke after oil change

    Sometimes the oil pressure would display correctly and other times not.
  10. L

    MEP 803A smoke after oil change

    I’ve had a knot in my stomach since I first saw the smoke from my unit but it has eased a little after seeing your videos. I was scared to run it very long, but you think let it run to clear up? Nearly identical amount/color as your smoke. It was clean burning with the unknown old oil in it...
  11. L

    MEP 803A smoke after oil change

    15-40 conventional. Oil pressure gauge went from 45-50 psi to pegged at random.
  12. L

    MEP 803A smoke after oil change

    Hi, I recently changed the oil/filter (Wix and Rotella) and now shortly after startup I’m getting an unusual amount of smoke. 2100 hrs. New to me set and it did fine (no smoke) before oil change. I have a video but I can’t upload it. The TM I looked at didn’t go into much detail about...
  13. L

    MEP-803a possible battery short

    I wondered that. It’s a cheap 8 amp $35 Schumacher from the box store. I’m going to take the battery to the Interstate Battery dealer tomorrow and let him test it.
  14. L

    MEP-803a possible battery short

    I unhooked all cables from the terminal posts before I charged the first battery.
  15. L

    MEP-803a possible battery short

    I’ve got a similar situation, two new batteries about a month ago. This week, the unit is dead, charge one battery yesterday, another today. On the second battery, the charger says “swap clamps” like the polarity is reversed on the battery. I will investigate more this weekend.
  16. L

    Which NOCO Genius Charger for MEP-803A?

    I may have mistakenly understood that I needed a 24V charger for the gen set. Basically and dual bank 12V charger will work?
  17. L

    Which NOCO Genius Charger for MEP-803A?

    I may have read this thread incorrectly, but it seems like most recommend the NOCO G7200 24V charger which is no longer made. Question 1 I need to use a dual bank 24V charger on my MEP 803 and wire it to both batteries while they are connected to the get set? Question 2 If I use a dual bank...
  18. L

    Generator auction prices

    And the market for used runners 🤦‍♂️. Can’t touch a used one for less than $5k or $6k and it’s beat to hell from the 90’s. Not knocking capitalism one bit, just not buying another one right away.
  19. L

    MEP-803a 60 amp connection?

    This is what I’m going with, there is a thread further down. I had the same OCD issue potentially pulling 60 amps from 50 amp plugs. This plug is rated for 60 amps.
  20. L

    MEP 803A Home Backup Wiring/Cleaning

    I I have an Eaton CH meter combo, I am certain eaton makes an interlock but I will probably source that item from the local electrical supply house to ensure I get the correct one.