    Mep-003 fuel cap

    Is the fuel cap off the mep gennies interchangable with a cap off of an an m35a2? Mine are pretty cruddy, was thinking a new deuce cap could be had cheaper.
  2. D

    Mep-002 stator

    I'm working on my non charging mep-002. I had removed stator wires and got a reading of 42 volts (meter set to ac) . Before I go and pull blower wheel and assume stator is bad is there anything simple I could be overlooking. When I look behind blower wheel it appears that stator has quite a bit...
  3. D

    Mep-002 voltage regulator (D.C)

    I have a new voltage regulator I am going to be wiring up to an mep-002. I can see that the top two wires go to the fuse located by injector pump. That leaves three wires at the bottom. One has a red label on it, my question is does it matter which order the remaining two wires get put on ? They...
  4. D

    Mep-016b voltage reading

    I checked the batteries with a multimeter with the set running and I'm getting a reading of 30 volts. I'm thinking thats quite high. Whats the norm for these sets? I checked the technical manuals nothing for the mep-016b. I proboly can get one from delks but it would help if I knew where its...
  5. D

    Mep-016b hertz guage readings

    When I start my mep-016b up I let it warm up then dial it in to 60 hzs via the fine throttle knob.. I plugged our chop saw in the shop to the convienance outlet when I start the saw up and put a load on the generator the hertz guage pegs out all the way to the right 64-65 hertz. Is something...
  6. D

    mep-106b lugs

    I just got ny mep-016b gen running (bought last year gl) I have never used the lug style connections. Do I just strip wire back and insert in slot and and crank nut down on wire? Looks narrow as like you would be doing good to fit a #10 wire in there. I thinking of getting a distribution box...
  7. D

    Mep-003 smoking

    I recently acquired a mep-003. Upon start up it smokes excessively. Talked to Delks he said they all tend to do that for first 3-5 minites. Here is my question one set of cylinders clears up quite qucik approx 2 minites and the other set takes more like 8-10 minites to clear up. I pulled those...
  8. D

    Mep-003

    I just bought an mep-003 gen. I am going to use this for back up at my house. I wanted some opinions on hook up. I'm thinking of using a 200amp transfer switch (manual) . I'd like to have a 75 ft (max) cord to get gen away from house. Is #8 copper sufficient? If I can use a smaller transfer...