  1. charger53

    mep 004a help

    Thanks for all the help! That did the trick. Overload relay was bad. We are up and running. All works as it should. Thanks again!!
  2. charger53

    mep 004a help

    Got it! For 45.00 i will just replace it. Its less money and time than driving 100 miles to find someone who has the equipment to check it.
  3. charger53

    mep 004a help

    upon further investigation I have discovered that the breaker will close when the set is in battle short mode. Turns out I wasnt holding the breaker switch long enough..... So the set operates as it should in battle short mode putting out correct voltage. I still do not have a understanding as...
  4. charger53

    mep 004a help

    Yes, set is in single position, I will bypass k13 and give that a try tonight if the weather permits. Thanks for all your help again. I am terrible at military style manuals, they just dont fit well with my brain. The help you have provided would have taken me weeks to figure out and I would...
  5. charger53

    mep 004a help

    I have tried that as well, ouput circuit breaker will not close with the close switch even if the battle short is up when the set is running. It will only close if the set is in battle short and not running. I will verifiy this again tonight when I get home, but I did try that. The set is...
  6. charger53

    mep 004a help

    I dont no what a UOC is, and there are no electrical shops within 100 miles. I am a car guy and have a good multi meter and thats about it. Usually the best bet for me when it comes to complex electrical is to replace the part with a known good unit, in this case looks like that would set me...
  7. charger53

    mep 004a help

    Looks like ebay has them available. I will go through the TM again tonight for test procedure to see if I can deciper it. Thanks for your help! I needed a boost getting started! If you have any other info, please feel free to let me know.
  8. charger53

    mep 004a help

    Sorry, should have been more specific, it is the thermal watt converter. The freqeuncy transducer look fine from the outside. If you believe this is the source of the problem, do you know where I can get a replacement? I am very mechanically adept, however generator function is all new to me....
  9. charger53

    mep 004a help

    I have a Mep 004A that has a overload light on. The set is putting out correct voltage to the overload relay input side, but of course no voltage at output side. If I battle short the set before start up the relay functions as it should, however the set has no power to start on battle short. I...
  10. charger53

    Mep 004 overload

    I will give it a try and report results as soon as I am home again. Thank you! Very little time at home right now, so not much time to work around the ranch ;)
  11. charger53

    Mep 004 overload

    I recently had a lightning strike about 10 ft from my genset. Started it to do my pre winter load test the other day and it shows overload on the indicator lamp. The generator doesnt put out voltage at the lugs, but does show everything as should be on the guages. Im thinking overload relay. Can...
  12. charger53

    m923 Transmission is making a buzzing sound when I put it in 1st or reverse

    Mine makes a vibration noise idling in first or reverse. The trans seems fine and hasnt had any problems. It pulls well and shifts strong. I have always thought it was normal
  13. charger53

    M923 Installed wet kit and Hoist with auxilary hydraulics

    I was hoping to find a "factory" valve for dump just so it would mount in the same location, but will most likely use the northern tool valve. I have had a full load of wet sand on it and had to raise the pressure in the valve with a stronger spring in the pressure relief on the valve. It was...
  14. charger53

    Glass dimensions for M923a2 please

    Mine drags on the window seals and is very hard to roll up with the doors closed. You can use silcone lube in the edge window tracks to help some when the door is open. I plan on taking all the window seals off and designing something that fits better and maybe seals one day before winter... I...
  15. charger53

    Glass dimensions for M923a2 please

    If you have one cut be sure they use safety glass designed for a windshield. If something should happen.... even a large rock you will be glad you did.
  16. charger53

    Mep 004A neutral / ground bond question

    I have a MEP 004 that I converted to singe phase to provide backup power for my house / barn and whatever else. I have the electrician coming next week to install a 200 amp double throw transfer switch. My confusion is the correct location to remove the ground / neutral bond. Can anyone tell me...
  17. charger53

    M923 Installed wet kit and Hoist with auxilary hydraulics

    After searching and researching my options for installing a dump hoist on my M923 I came up with all the components to install a PTO driven hydraulic pump and all the additional components to make the hoist and auxiliary hydraulics to run a dump trailer that I made from my 200 series generator...
  18. charger53

    Another CTIS Problem!!!!

    I don't want to hijack the thread, but since it is a CTIS thread, Does anyone know if the air release valves where it splits at the axles can be rebuilt? My rear one leaks, lets the whole system flatten all the tires unless I unplug it.
  19. charger53

    Utilizing M925 stock hydraulics

    I used the winch valve for my dump since I didn't have a winch, However looking through the TM's I did see that the dump trucks with winch have a dual valve to control both the dump and the winch. If you could get one of those that would be the easy way. I put a diverter valve in after my...
  20. charger53

    Using 5 ton cargo trucks for adventure type ventures

    I have had the ABS light come on one time. It was accompanied by a lower tone than the air buzzer annoying noise. could have been something else, but as soon as I found the wire unplugged in the abs and restarted the truck the buzzer went away to.
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks