• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. R

    MEP803A Does not crank Hurricane on its way.

    Thank you. I have these. My issue was identifying the numbers for the terminals on SW1 itself without removing the switch and wiring.
  2. R

    MEP803A Does not crank Hurricane on its way.

    Roger. I just jumped it long enough to hear the pump test. That's the issue. Can you send me a PM. I have a guy locally that has the diodes since I deploy on Monday, but I would like to talk to you about your remote starts. There are 3 of us on the ship that use these as our house backups...
  3. R

    MEP803A Does not crank Hurricane on its way.

    Okay we need to back up. I mis read the label and measured the wrong diode. The right side of CR1 has voltage and the left side does not in prime/rum
  4. R

    MEP803A Does not crank Hurricane on its way.

    112 a correct? 122a was a typo?
  5. R

    MEP803A Does not crank Hurricane on its way.

    See below for values. Is there a drawing for s1. I can not see terminal 2. 1) Right big stud on MT4 behind the gauge panel--25.3vdc 2) Left big stud on MT4 behind the gauge panel-25.3vdc 3) The right side of CR1 in the back left corner behind the gauge panel (The labeling of the parts there...
  6. R

    MEP803A Does not crank Hurricane on its way.

    MEP 803a does not crank. Power available at CB-1. Main switch voltage across #6 is 25vdc in stop and 0 at prime/run. The relays and fuel pump do not click. Generator started and ran fine 2 days ago with a normal shutdown after a 2 hour load test. No warning/alarm lights. Fuel level is...
Top