Have a MEP002 that will not start until I turn the adjustment screw on the starter lockout switch.
Have already replaced the starter, batt, cables and lockout switch.
Referred to p 4-32 of TM5-6115-584-12 to set gap at 040 but
unable to set adjustment screw at 040 with genny running-too much vibration ect.
Is there a way to bypass the switch so I can start the genny and later work through the gap adjustments with the starter lockout switch?
When I try to start, I just get a loud metallic click from the area of the fuel pump as the solinoid moves. This continues until I remove the starter lockout switch cover and try to adjust the points. Then it will start, then restart. However after several days pass, I am back to click only and no start.
Thanks
Have already replaced the starter, batt, cables and lockout switch.
Referred to p 4-32 of TM5-6115-584-12 to set gap at 040 but
unable to set adjustment screw at 040 with genny running-too much vibration ect.
Is there a way to bypass the switch so I can start the genny and later work through the gap adjustments with the starter lockout switch?
When I try to start, I just get a loud metallic click from the area of the fuel pump as the solinoid moves. This continues until I remove the starter lockout switch cover and try to adjust the points. Then it will start, then restart. However after several days pass, I am back to click only and no start.