Ok, so I took the starter off of the running Mep-002 and installed it on the Mep-002 that I could not get started, due to a bad starter I believed. Once I put the known working starter on the Mep-002, and upon turning on the start switch it activated the fuel rod at the IP and cranked over just fine. So it turns out that the starter or solenoid are bad, so I will drop it off at the repair shop, he already has a 24 volt solenoid waiting for me. The generator started but I had to manually push the fuel rod all the way up and hold it there for it to keep running and it was only running on one cylinder. it was trying to run on both but just couldn't do it, I think the IP might have some residual bad fuel in it still. The fuel rod seemed like it was almost all the way up, and me pushing on it only moved it a fraction of an inch but I am guessing the pump might has alittle crud in it, Thoughts????