Oil filter cans that retain oil?

oddshot

Active member
781
119
43
Location
Jasper, Georgia
OK ... The front passage is 11/16". Also, an 11/16" drill fits in the hole as if it were the drill that made the hole.

Yesterday, I did NOT measure the rear hole, I didn't think that you would want that one, but now I see why you would.

That hole is 23/32 inch or about 1/32" larger than the front hole. I confirmed this measurement with a 11/16" drill bit as well.

Ted
 

rustystud

Well-known member
9,280
2,987
113
Location
Woodinville, Washington
OK ... The front passage is 11/16". Also, an 11/16" drill fits in the hole as if it were the drill that made the hole.

Yesterday, I did NOT measure the rear hole, I didn't think that you would want that one, but now I see why you would.

That hole is 23/32 inch or about 1/32" larger than the front hole. I confirmed this measurement with a 11/16" drill bit as well.

Ted
It should still work. I went into town and talked with the guys at the Hydraulic supply store. They don't stock this item but there sister store does. After calling them I found out there is no way to order it until after Christmas.
 

welldigger

Active member
2,602
15
38
Location
Benton LA
The only other option is a 3 PSI valve. I feel the weight of the fluid would overpower it. There would be no restriction to using a 15 PSI valve as the main pump pressure is over 100 PSI .
I would use the 3 psi valve. The oil in the cans doesn't weigh nearly enough to crack that valve when the engine is off.

For example if you have a 1ft column of fresh water at the base of your column you will have about 0.45 psi. So it would take a 6ft column of water to equal slightly less than 3 psi. Water is more dense than oil. Therefore it would take an even larger column of oil to equal 3 psi.
 

rustystud

Well-known member
9,280
2,987
113
Location
Woodinville, Washington
But don't the filter bypass valves open at 15psi? I would think 10 would be better for this, maybe 5.
The filter bypass valve opens at a "Differential" pressure of 15 PSI. That means if the main pressure coming in is 100 PSI and the oil coming out of the filters (due to blockage) is only 85 PSI , then the bypass will open allowing the oil to "Bypass" the filters.
By having the check valves "crack pressure" at 15 PSI , allows the oil to remain in the filter housing without undue leakage. The higher the crack pressure, the more tightly the valve will seal.
 

cranetruck

Moderator
Super Moderator
Steel Soldiers Supporter
10,350
75
48
Location
Meadows of Dan, Virginia
I'm a fan of oil filters that drain. Just think of an oil pan heater that will then heat all the oil for an easy start in the Winter without bypassing the filters, where the oil may otherwise be to viscous to flow. IMHO, the reason they were designed to drain in the first place.
 

welldigger

Active member
2,602
15
38
Location
Benton LA
The filter bypass valve opens at a "Differential" pressure of 15 PSI. That means if the main pressure coming in is 100 PSI and the oil coming out of the filters (due to blockage) is only 85 PSI , then the bypass will open allowing the oil to "Bypass" the filters.
By having the check valves "crack pressure" at 15 PSI , allows the oil to remain in the filter housing without undue leakage. The higher the crack pressure, the more tightly the valve will seal.
Not always true. A 15 psi valve won't seal any better than the 3 psi valve. Also a 15 psi restriction upstream equals a much higher psi restriction at the oil pump. You may end up causing the oil pump bypass to open and starve the rest of the engine of oil.
 

rustystud

Well-known member
9,280
2,987
113
Location
Woodinville, Washington
I'm a fan of oil filters that drain. Just think of an oil pan heater that will then heat all the oil for an easy start in the Winter without bypassing the filters, where the oil may otherwise be to viscous to flow. IMHO, the reason they were designed to drain in the first place.
Cranetruck, no one is forcing you to have quicker oil pressure. If you like the old way of 3 to 5 seconds of no oil that's your right as an American.
 
Last edited:

welldigger

Active member
2,602
15
38
Location
Benton LA
When you add a restriction upstream from a pump the pressure gets greater the closer you get to the pump.

A 15 psi valve isn't going to seal closed any better than a 3 psi valve. It just takes more pressure to open it.

What I'm getting at is there's no need to over do it on the opening pressure of the check valve. Your just adding restriction to the oil flow.
 

rustystud

Well-known member
9,280
2,987
113
Location
Woodinville, Washington
When you add a restriction upstream from a pump the pressure gets greater the closer you get to the pump.

A 15 psi valve isn't going to seal closed any better than a 3 psi valve. It just takes more pressure to open it.

What I'm getting at is there's no need to over do it on the opening pressure of the check valve. Your just adding restriction to the oil flow.
In a hydraulic system, the pressure is the same anywhere along the line until after you pass a restriction. As the pump puts out over 100 PSI, the 15 PSI crack pressure is nothing. The spring pulling the valve closed is stronger in the 15 PSI then in the 3 PSI, thus making a better seal. If you want a 3 PSI valve you can buy one. As for me I'm going with the 15 PSI valve.
 