ItWasntMe00
New member
- 6
- 1
- 3
- Location
- Colorado springs, co
I have a MBU v3 that doesnt hold its flame I replaced the nozzle and flame sensor, fuel filter and air filter. if anyone have any ideas to try please let me know.
Thanks
Thanks
Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Yes starts on full power then after a few seconds it dies put, and yes I have read through the tm and it says flame sensor but it's been replaced.So, it starts okay on full power (flame) and then dies? Or does it flicker but stays lit? Have you read through the TM? I do have nos pumps and fuel blocks if you need them but give a little more detail about how it's not holding a flame. I will look through the TM in the morning.
Now im.not getting any flame or fuel to the nozzle idk what's going on nowHave you checked the compressor? maybe not enough compression to atomize the fuel . sort of like great air pressure when you start the air tools, but wains?
I did and it was er01 which doesn't make sense because I change the Nozzle, fuel filter, and air filter aswell as the flame sensor so I have no idea what this thi g is doing.You should be getting an error code. The meanings are found in Work Package 008 of the TM 10-7310-281-13P.
ER01 No Flame or flameoutI did and it was er01 which doesn't make sense because I change the Nozzle, fuel filter, and air filter as well as the flame sensor so I have no idea what this thing is doing.