southdave
Active member
- 1,986
- 6
- 38
- Location
- ripley, oh/TDY Lordstown,Oh
I bought an electric fuel pump it delivers 8psi to the IP, while checking spec. on the existing mech. pump I found this: out of the trouble shoting tm
engine for 15 seconds. Container should be at least
Check fuel pump operation. Disconnect input fuel line at the fuel filter. Disconnect
pink lead from fuel injector pump. Use a quart capacity container, and crank
pink lead from fuel injector pump. Use a quart capacity container, and crank
engine for 15 seconds. Container should be at least
¼ full or contain ½ pt (0.231)
My question is this going to create problems for me down the road? I am installing a turbo and planed on routing my oil though a block off plate where the mech pump is located. would apprec. any feed back maybe the filter diff. pressure would compensate for the increase in pressure?
of fuel. Install low pressure gage in fuel line. Crank engine for 15 more seconds.
Fuel pressure should be 5.5-6.5 psi (38-45 kPa). Reconnect fuel inlet line to fuel
filter, and reconnect pink lead to fuel injector pump.Fuel pressure should be 5.5-6.5 psi (38-45 kPa). Reconnect fuel inlet line to fuel
My question is this going to create problems for me down the road? I am installing a turbo and planed on routing my oil though a block off plate where the mech pump is located. would apprec. any feed back maybe the filter diff. pressure would compensate for the increase in pressure?
Last edited: