  1. cpf240

    CUCV M1009 Blazer will not start

    Have the batteries load tested by the auto parts place. Just because they show a full charge doesn't mean they can handle the load.
  2. cpf240

    Alternator wiring question

    If the bulb doesn't work, the alt won't charge. I'd start by replacing the bulb.
  3. cpf240

    IL - M1009 Will Not Start

    The battery disconnect is on the negative terminal of the front battery only? That would still leave the rear battery in the circuit, and I seem to recall reading posts here on SS where that can lead to bad things. Usually this comes up when someone is trying to stop a runaway starter, and they...
  4. cpf240

    New Glow Plugs Installed; Starts Worse Than Ever

    What voltage did you see? And you tested the two glow plugs at 24v? The glow plugs run on 12v, not 24v. That is the reason for the resistor, to form a voltage divider network with the glow plugs to provide them with 12v.
  5. cpf240

    IL - M1009 Will Not Start

    I'm not sure on the GPR109. This is from the CUCV Wiki: "GP Relay is NAPA# ST85, Advance Auto #S603 (AA is much cheaper)"
  6. cpf240

    M1009, Marietta area, Voltmeter needle going to red on right side of meter.

    Without a meter, it is hard to say, given that you said the volt meter in the truck is suspect. If it is reading correctly, then yes, it looks to be an over-charging condition. Without a way to test the output of the alts, you might want to pull them and have them tested. Just because one is...
  7. cpf240

    IL - M1009 Will Not Start

    Is the new GP relay an isolated-ground unit? Meaning that there is no conductivity between the mounting tabs and either small terminal? The GP relay is activated by the GP card grounding the blue wire. The other one is hot at all times when the key is on. So, if the GP relay is not an...
  8. cpf240

    IL - M1009 Will Not Start

    Can you post a picture of the GP relay wiring? The description is a bit confusing to me.
  9. cpf240

    M1009, Marietta area, Voltmeter needle going to red on right side of meter.

    Agreed. Look for the Harbor Freight coupons, they often have a cheap DVM for free with any purchase. You'll need to get voltage measurements to be determine what is going on.
  10. cpf240

    Volt Meter Connections for Rosscommon Conversion Single Alt.

    Please re-read Warthogs post above yours. The orange wire is hot at all times and goes to the gauge, not the light. The black (not the white/gray) wire is the ground wire for the gauge, and is switched via the relay. The stock gauge is isolated from the rest of the dash, so does not get its...
  11. cpf240

    Not a great way to celebrate Veteran day!...CUCV lost power and died on freeway

    Ok, didn't know it had a turbo... doubt the IP would make it run hot, but the heat could affect the IP. Could try pouring cool water over the IP and see if it runs, but it sounded like it had time to cool off before you tried to start it again.
  12. cpf240

    Not a great way to celebrate Veteran day!...CUCV lost power and died on freeway

    I'd suggest replacing the short section of return line on the IP with a clear one so you can see if you are getting air in the lines or even enough fuel. If no fuel, the filter might be clogged, even if it is newish. If air, have to trace down the leak. Might also want to pull the cover off the...
  13. cpf240

    Suggestion and Opinion on Changing Rear Bearing Seal?

    Sometimes a bad/dirty/clogged CDR valve can cause excess pressure in the crankcase resulting in oil leaking past the rear main seal. The CDR valve can usually be cleaned and reused.
  14. cpf240

    Should I be worried about not having done doghead relay?

    You'll need to verify how it is wired first. The DH relay mod is an attempt to address the issue of the, shall we say, less robust relay from the factory. So, if your push button is still using the relay, then it could still suffer from the stuck relay issue. If it bypasses the relay, then there...
  15. cpf240

    Can't see the instruments at night

    I'd start with a good cleaning of the cluster, circuit board, housing. Some members have repainted the back part to be more reflective, with either white or silver paint. LED bulbs can be used for all lights with the exception of the GEN1 and GEN2 bulbs. It is also possible that the rheostat in...
  16. cpf240

    Kats Circulating Heater Install Problem

    http://www.jatonkam35s.com/cucvwinterfront.htm
  17. cpf240

    M1009 horn problem

    There is a diode under the tape on the back of the horn relay. It is probably shorted. It can be removed, and does not need to be replaced.
  18. cpf240

    No battery power.

    By this are you saying that the switch is in the "service lights on" position?
  19. cpf240

    going back to 24v

    Are you sure it is an isolated ground alternator? Test it with an ohm meter between the ground stud and the case.