  1. DieselAddict

    MEP831 muffler crack

    Yep, you guys called it 100%. One screw loose and one missing.
  2. DieselAddict

    MEP806A Double Delta Single Phase

    Have you verified its a 12 wire head? My understanding is that everything 804 and above are 10 wire heads.
  3. DieselAddict

    Any of you win those A427B load banks??

    If they hadn't been so far away from me I would have been bidding on them. I expect they will show up on ebay for $3k each like I've seen with others. :(
  4. DieselAddict

    MEP831 muffler crack

    Thanks for info. I will check those for sure as I work on the repair.
  5. DieselAddict

    MEP831 muffler crack

    I started up the 831 yesterday to charge batteries and noticed some soot coming out of the gap in the insulation wrap between the exhaust tube leaving the engine and the main muffler body. Pulled back the jacket as much as I could and noticed a crack radiating out from the welded fitting. I'll...
  6. DieselAddict

    Portable distribution block recommendations

    You are correct. Load is load. Even an imbalanced load does work so its not an efficiency problem. The diagram is a simplified version of an alternator. There will be more pole groups than is represented so the rotation distance between peaks of magnetic flux will be a lot closer together...
  7. DieselAddict

    Portable distribution block recommendations

    I fell like I should probably let you off the hook at this point. I was asking those questions to make the point that the return path doesn't matter in regards to fuel efficiency or energy waste. The engine won't be loaded any differently whether a 5kw load is split equally between L1 and L2...
  8. DieselAddict

    Portable distribution block recommendations

    Doesn't all energy that leaves the head have to return to it?
  9. DieselAddict

    Portable distribution block recommendations

    Why is energy on the neutral not performing work?
  10. DieselAddict

    Portable distribution block recommendations

    Could you expand on how an imbalanced load affects fuel efficiency?
  11. DieselAddict

    Connecting 2-200 amp panels

    Another option is to do a KIRK key interlock system between the main breaker and the generator breaker. The lock on the main breaker is key retaining so when its turned on the generator breaker is locked open by the same key. You would have to open the main breaker to remove the key. Take the...
  12. DieselAddict

    With freezing rain forecast for central NC, time for a generator test

    I'm OK with snow but the ice we get here sucks. Thankfully the storm spared us this time and it came down as all rain. Still a chance for something tonight but lower probabilities.
  13. DieselAddict

    With freezing rain forecast for central NC, time for a generator test

    Wanted to give a bit more info about my generator test. I've been using the generator lightly loaded on a new piece of property I bought earlier in the year. I've not been able to put much more than a 10% load on it for the last 30 hours of run time. Yesterday I brought it home and gave it a...
  14. DieselAddict

    With freezing rain forecast for central NC, time for a generator test

    Tonight in central NC we have the potential for a bit of freezing rain. That can be a really bad time here if we get trees down on power lines this far out into the woods. Figured it was time to give the MEP803 a bit of a workout. Warmed it up and increased the load till we got it a bit over...
  15. DieselAddict

    Advice needed. Which genset for off grid?

    I'm happy to share how my setup is done. Feel free to ping me off line.
  16. DieselAddict

    MEP-803A won't start

    Batts be toast. You may be able to recover them some with the right charger but it’s better to replace them.
  17. DieselAddict

    Advice needed. Which genset for off grid?

    You can find them at auto auctions. Now that an economy that has sprung up around repurposing these batteries its hard to get them before the companies that resell them snatch them up. As and example the 40kw/hr of batteries cost around $1,500 because I bought them directly from junk yards but...
  18. DieselAddict

    Advice needed. Which genset for off grid?

    It is split phase so 120/240 output. It can be converted to straight 120v for use in a multi-inverter setup doing either split phase or with 3 of them it will do 3 phase.
  19. DieselAddict

    Advice needed. Which genset for off grid?

    Yes it does come in 48v. I'm using the Schneider XW+6848 inverter. I'll be getting a second one to power the workshop on the new property along with its MEP802 partner. I'm using the batteries from electric cars to run the inverters. The 40kw/hr pack is from Chevy Volts and the pack for the new...
  20. DieselAddict

    Advice needed. Which genset for off grid?

    To as a What is your budget? Does your inverter parallel with an incoming power feed? I ask that because the XW+ inverter I have does. I can program the inverter to the output capacity of the generator and it will charge my batteries from the generator while passing through any excess power...