The way these are tapped you have three outputs l1 l2 l3 each one of them is 120 volts to l0 and in between each one of them l1 l2 l3 would be 208 volt
With those voltages I would guess that you are wye tapped in your service and it wouldn't surprise me if you could adjust the generator up to put out 125 and 219. Or close enough.
What you do want to do is make sure you have all three outputs loaded somewhat the last thing you want to do is...
Okay, simple math is that things going to put out about 250 amps and in order to prevent it from wet stacking you're going to have to load it to somewhere around 200 amps. Not to mention it's going to pull about 2 gallons an hour.
I think you're looking at some massive Overkill (and this is...
That being said that's a very big generator
How big of a load do you need to drive especially single phase and what's your intended use for this cuz it's going to suck fuel like it's going out of style
It should be a 12 lead head so physically it's possible the gotcha is how the other control systems are tapped into the reconnection board and how to reroute them in a manner that doesn't let the magic smoke out of some very expensive components
Thanks all, Ive had to order some tools I might try to get a boreoscope into the cylinder soonish (I leave on a trip soon so tinker time is short). When I do get some info I'll update.
Sheps hurricane rules:
Never let the car below 3/4 before the storm
Have enough generator fuel for 72 hours.
If you are trying to buy gasoline:
wear a helmet
dont go to stations off of major roads/ exits
P.P.P.P.P.P. Prior Planning Prevents Piss Poor Performance. I have festoon lighting over the pool in the back yard, its programmed to come on every night so my neighboorhood is pitch black except for my house being lit up like a friggen Christmas tree
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!