  1. cpf240

    Another starter issue

    If that relay is clicking when you connect it, but the key is off, then I'd leave it out until you trace the problem. I'd guess either an out of adjustment ignition switch, or a bad ignition switch. As for it not cranking at all, perhaps that was the problem the previous owner had with it... the...
  2. cpf240

    CUCV oil pump acting funny??

    This is exactly what I was told was the reason our '94 Ford Explorer used a dummy light switch for the oil pressure gauge. The Ford tech said they got too many complaints from owners that the "oil pressure dropped at stoplights" etc... So they soldered a resistor to the back of the instrument...
  3. cpf240

    Blackout lights won't switch off

    As I recall, the left switch only controls the blackout driving light, not the ones in the bumpers. The bumper blackout lights *should* turn off with the right switch being in the off or service light positions.
  4. cpf240

    Help...on road now and truck wont start

    My understanding is that the fuel shutoff solenoid gets hot and stops working, so the cool water gets it going again. If so, then replace the fuel shutoff solenoid.
  5. cpf240

    Fav/Dpv 1009

    Its all relative... relative to the other CUCVs, the M1009 is a rocket....
  6. cpf240

    Shifting issues

    You could look in the -20p and -34p TMs and get the GM part number, then google it...
  7. cpf240

    Jump Starting a M1008

    I think you answered your own question. One, or both, of the batteries is bad. If the bad battery has a short, I don't think it will start, even with a jump.
  8. cpf240

    need advise Starter and Electrical issues

    Could also be a bad switch in the steering column causing the DH relay to stay engaged. Simple test with a meter, or your ear, to see if the DH relay is engaging when the cables are connected. I'd disconnect the solenoid wire from the starter before testing though. Should tape it off as well, to...
  9. cpf240

    Glow Plug Relay Only Thing Missing?

    The small wire that is part of the dog bone cable from the front battery positive terminal to the rear battery neg terminal feeds the 12v distribution block over next to the brake master cylinder. When doing the 12v glow plug bypass, the power for the glow plug relay is often run to that 12v...
  10. cpf240

    Shifting issues

    I'd suggest using a vacuum gauge to see if the vacuum pump is working properly.
  11. cpf240

    CUCV GlowPlugs

    It is my understanding that the portion of the GP harness that connect to the individual GPs is made from fusible link wire. If it is burning up, there may be one or more GPs that are shorted to ground. Take a look at the TMs for the GP system diag procedure. A simple multimeter will tell you...
  12. cpf240

    M1009 New IP, now won’t turn over

    I'd suggest reading the Fusible Link sticky at the top of the CUCV forum.
  13. cpf240

    m1028 starting issue

    It could be a number of things. Perhaps the relay, or the temp sender, or the card, bad glow plugs, etc. A volt meter and the troubleshooting steps in the TM should pin point the problem. You could try jumpering the two big lugs on the glow plug relay for 5 seconds or so, and then try to start...
  14. cpf240

    CUCV Build... Here We Go Again...

    Before that happens, I'd like to know what happened, why no updates, etc. I looked around a bit, but didn't see anything explaining why it was not finished. Thanks.
  15. cpf240

    Newbie needs help on a 925 No Start.

    While Doghead may know what that is in your picture, there are others that may come across this thread that do not.
  16. cpf240

    Learned something new!

    I thought it was just the fuel shutoff solenoid on the IP that is the problem, not the pump itself...
  17. cpf240

    Rapidly clogging fuel filters... Sand in fuel?

    M1009... only one fuel tank, does not use saddle tanks.
  18. cpf240

    M1008 or M1028

    And the people that post on internet forums are all English majors who never misspell anything, always use correct grammar and actually know what they are talking about?