I found a very nice set up controlled by a thermostat. In theory I should be able to place one up high and one down low just turned around to blow air in. The Louvers close when they are off and seal the shed back up. The fans are 3200 CFM each. Think that’s enough to control the heat in the...
The sheds down here are anchored into the ground and build to 150mph wind speeds. I also added OBS board interior on top of that. Which should strengthen it up a ton.
I am a TIG welder by trade so I assume I’ll be making a plenum and flex duct. Lol was just hoping the military made something for that option. If they even run them indoors for some reason
Looking for some ideas, I want to store and run my 803a out of this shed. I have a couple questions.
1. I want to make a 90* turn straight out of the side with the exhaust. Then another 90* elbow facing downward. This should keep the rain out. I’m thinking up with an exhaust flap may be bad. I...
Does anyone know the quality of the stock fuel water separator on an 803a verses a WIX fuel water separator? I can’t seem to find out any info as far as micron rating on the stock ones. I found a couple new in box ones for sale. Reason being is the drain valve setup is much cleaner on the stock...
Thanks for the help guys I was able to locate the TM thanks to the help from guyfang. Also owns able to order the bulbs and covers. I could only find the cover in red but they work just fine. Below is the part numbers and suppliers I found. Thanks guys
So can I just go with the max output my 803 is rated at and then pick THHN that is rated far above that? I am not worried about saving a couple bucks. Is a 100’ run ok as long as the conductor is rated well above machine capabilities? Looking to hardwire permanently one a location.
Thanks! I was able to open it and find the part number. When I confirm the ordered parts are correct I will finish the thread with them. For anyone in the future
Might anybody know where I can find the small bulbs on this switch, I found the larger ones on line. I have no TM for it and can’t find the part number. Also if someone had a TM that would be great!
I bought a reset 802a rebuilt lister, I understand they vibrate naturally, I’m almost sure what I am experiencing is not right due to the fact that it will vibrate harder at some times then run smoother at other times. Can you please explain turning the injector pump? Sorry if my terminology is...
Need some help with using these 5kw dryer elements for a load bank. I understand I will need breakers, fan’s, housing etc. I’m not sure how these are wired, is it #1 = 120 and #2 = ground? I read another guys post on this topic. But the wiring specifics I still need. Thank you