  1. yohanusmarcus

    MEP005A frequency meter not working.

    No go on the batery test.
  2. yohanusmarcus

    MEP005A frequency meter not working.

    I did take the meter and transducer out applied 110v ac and still nothing on the frequency meter I'm getting about 1.5v DC out
  3. yohanusmarcus

    MEP005A frequency meter not working.

    I had to open stuff up to find that out
  4. yohanusmarcus

    MEP005A frequency meter not working.

    Lol that's great. I've looked at them and followed the one on start up and shutdown every time I start the machine.
  5. yohanusmarcus

    MEP005A frequency meter not working.

    Yes I can follow a wiring diagram just unsure on some symbols.
  6. yohanusmarcus

    MEP005A frequency meter not working.

    Yes I'm sorry for the misinformation. That was before I got the machine unloaded and could actually put a meter on the output studs, I was going by the meters on the machine. So I have an issue somewhere that is cutting fuel off is that correct? Should I check the speed switch first?
  7. yohanusmarcus

    MEP005A frequency meter not working.

    Ok what do I need to work on first. 1. Machine will not stay running without battle short on. No fault lights on at all. The connection board is in the 120/208 configuration and I get 189 v 0L to L1, L2, L3 and 338 v phase to phase regardless of engine speed. 2. A11 has burned transformer and...
  8. yohanusmarcus

    MEP005A frequency meter not working.

    Ok my bad. So if I get the ADVR my panel will still function as it should? Right now as the machine is everything works, it produces power, but the frequency meter does not work. If anything I'm running at or above 1800 RPM with the throttle control knob pulled most of the way out.
  9. yohanusmarcus

    MEP005A frequency meter not working.

    Was just talking to my wife about this. Currently all my meters work except for the frequency meter and if I understand right that might be a symptom of th A11 being bad. I've hunted every where and can't find a replacement, or anyone who might rebuild it for me. I do think I could install the...
  10. yohanusmarcus

    MEP005A frequency meter not working.

    So should I invest in the ADVR054 OR try and find an A11. If I get one installed will all the meters still work correctly
  11. yohanusmarcus

    MEP005A frequency meter not working.

    Ok I just assumed on that one because it was part of the lot. I would appreciate the tm for it though thanks.
  12. yohanusmarcus

    MEP005A frequency meter not working.

    Thanks I'm not sure I'm up to the task but ill keep you updated.
  13. yohanusmarcus

    MEP005A frequency meter not working.

    So should I look for a new transformer or just the whole box
  14. yohanusmarcus

    MEP005A frequency meter not working.

    I also have a second mep005 that appears to be a precise machine that has no starter or ip I was considering as a parts machine
  15. yohanusmarcus

    MEP005A frequency meter not working.

    This is the A5 board
  16. yohanusmarcus

    MEP005A frequency meter not working.

    Yup finally found it. There are several wires that appear to have gotten hot in the past. From J15 to Tb101-2 and one from J10 to tb102-1. Along with the burned transformer, did just buy a boat anchor?
  17. yohanusmarcus

    MEP005A frequency meter not working.

    Might be an issue? Still looking for tb101.
  18. yohanusmarcus

    MEP005A frequency meter not working.

    I'm looking for it right now I have found the relays for overvoltage, reversepower, and short circuit. Am I looking in the right place? I see tb 105
  19. yohanusmarcus

    MEP005A frequency meter not working.

    Yes all lights lite
Top