Gee. Something was pulled and I didn't feel a thing. :-( I have all the connectors and plan to make the connection reversible as suggested. I chose wire #27 so the terminal block was controlled by the master switch through the relay I will install. Is #10 controlled the same way?
Gimp. Not sure what you mean by air connector. Do you mean connecting at the front airlock switch instead of the the master? I believe I am leaning toward using a dual connector off #27 at the master and feeding one side the the relay. Thanks,
I am installing a relay switch and terminal block to handle some 24V accessories (fan, dome light, etc) and I want to control the relay and terminal block via the master switch. My plan it to come off the #27 wire on the master switch to the relay. What is the best way to tie into wire 27?
Great new about the site update and the good things in your personal lives. I would also like to say your cudos to the mods only touches the value they add to the site. It is very clear to me that I would not have been able to do the things I have done on my MV's without this site as a...
I am looking for information on the correct position of the foam cowl sealwhich goes between the cowl and the windshield frame. I know the seal is glued on the bottom of the frame but I do not know if it goes in the center, toward the front edge or toward the rear edge of the lower frame. The...
Looks great Zout. You are a one man motor pool and body shop. Can't think on one thing you have not been able to do yet. Except of course, catch the perps. Thanks for posting.