  1. R

    "Rod Hall" GMV Suspension

    "Rod Hall" GMV Suspension Nice suspension. Rod Hall has some nice products for the platform. Unfortunately they are very dearly priced. Sent from my iPhone using Tapatalk
  2. R

    MEP-802a walking on smooth concrete floor

    Interested to hear how they work. Sent from my iPhone using Tapatalk
  3. R

    MEP-802a Power Quality (With oscilloscope pics)

    Very nice analysis. I was wondering about output quality of my 802. No scope to test... Sent from my iPhone using Tapatalk
  4. R

    MEP- 803A All Weather Enclosure

    Expense aside, non flammable materials might be a consideration in the event of a genset fire. Sent from my iPhone using Tapatalk
  5. R

    New to the MEP-802a

    Highly suggest changing out the fuel tank well plugs with brass/viton assemblies. The stock wellnuts will fail if not failed already. Check ultimate wellnut thread... Sent from my iPhone using Tapatalk
  6. R

    MEP-802 and 803 Main generator tip. MOD/MOV

    Added the MOV enhancement to my 802a today. Informative thread, thank you. Sent from my iPhone using Tapatalk
  7. R

    Another MEP-802 standby generator thread

    Generator is now fully reassembled. Used stainless screws (ref stainless thread). Replaced BUSSF03B 30A fuse so charging circuit works now. Replaced rubber battery terminal covers. Fresh oil and filter. MOV modification added. All set for load testing and winter storm duty...
  8. R

    turn signal cancel ring

    Anyone have pictures or a mockup? Sent from my iPhone using Tapatalk
  9. R

    turn signal cancel ring

    I was thinking exactly the same thing this morning Sent from my iPhone using Tapatalk
  10. R

    Another MEP-802 standby generator thread

    Yep, I’ll be running 10gauge 4 wire to the L14-30 plug. Since. I’ll be disconnecting the bonding strap since the unit will be connected to panel ground. Sent from my iPhone using Tapatalk
  11. R

    803 vs central air unit...no go

    Lol love the appliance load bank strategy [emoji106][emoji23] Sent from my iPhone using Tapatalk
  12. R

    turn signal cancel ring

    Have a pn#? Id spend 27$ Sent from my iPhone using Tapatalk
  13. R

    803 vs central air unit...no go

    It might need a hard start capacitor to reduce the starting current. Sent from my iPhone using Tapatalk
  14. R

    MEP-803A injector leak

    Ran the generator for 2 hours yesterday. No apparent leaking over the injector area anymore. Sent from my iPhone using Tapatalk
  15. R

    MEP-802 and 803 Main generator tip. MOD/MOV

    802a was reset in 2010. Fuse modification was done but not the MOV. Ordered a few... Sent from my iPhone using Tapatalk
  16. R

    Anyone have a Mep 802A fU1 FUSE or konow of an equivalent fuse (F03A125V30A) ?

    Sorry for the old thread activation. I also need a replacement FU1 fuse. Found a few on an auction site.... Sent from my iPhone using Tapatalk
  17. R

    MEP-803A injector leak

    One of the high pressure lines was not fully tightened. I’ll evaluate if the flares are cracked on next startup. Sent from my iPhone using Tapatalk
  18. R

    MEP-803A injector leak

    Looks like the high pressure lines not the return. Degreased and lightly pressure washed. Retightened the high pressure line fittings. Sent from my iPhone using Tapatalk
  19. R

    MEP-803A injector leak

    Looks like there is an external diesel leak originating from the injectors. Lines look ok, no leaks. Are there o-rings or other serviceable seals? Sent from my iPhone using Tapatalk
  20. R

    Another MEP-802 standby generator thread

    Sharing progress on my project to connect a MEP-802a to the home for backup power. Infamous well nut fix. Recommend starting with this first. My genset worked great however leaked after a few weeks. Electrical panel interlock installed. This required adjusting position of all breakers a...