  1. glassk

    MEP-004 Starting problems

    Dead Crank Switch,..??
  2. glassk

    MEP-004A Under Frequency Indicator Light

    Don't mind me, I'm just reading up, do you have a non-contact thermometer, while load testing, you can check the terminals and load wires for hot spots, sign of loose connections.
  3. glassk

    MEP-004A Under Frequency Indicator Light

    When I responded I had not seen the photo of the DC relay, It isn't thermal paste , but looks like either someone has worked on the control relay , or it has been hot enough to melt the encapsulating ?? Not sure which light is staying on, although the relay for remote sensing and Start stop...
  4. glassk

    MEP-004A Under Frequency Indicator Light

    Figure 3-123. Precise Relay Assembly, Exploded View item 30 is the under frequency relay, Table 2-2. TROUBLESHOOTING (CONTINUED) step 9 Defective under-frequency relay K12. Check relay K12. Replace if defective (para. 3-91).
  5. glassk

    What's going on? - Server Upgrade

    just playing, Thanks for all the unseen tasks it takes to keep this site running.
  6. glassk

    MEP002 mystical Shutter assembly

    TM5-6115-584-12 Figure 4-5. Adjusting Shutters Figure 4-6. Adjusting Thermo Unit from upper shutter. Adjust ball joint until upper shutter closes tightly on lower shutter when lower shutter is held closed. Re-attach ball joint to upper shutter. (2) Thermo Unit be figure 4-6). With Generator...
  7. glassk

    Homemade centrifuge

    I used 5.5 and got 1853,
  8. glassk

    Homemade centrifuge

    The guy next door has never mentioned anything, tht's his way of fishing, that I didn't have . saw PLC thread and while looking around surprized atwhat i do have , Offered somebody in WTB section a tent wall for $1 for the command post 11 x 11
  9. glassk

    Homemade centrifuge

    bottom is a stand alone temperature controller, will operate a heater to set point and takes several kinds of thermocouplers top right is your AC drive , and the top left is a 4 to 20 milliamp loop controller, I just have too much stuff
  10. glassk

    MEP-005A Load Bank Test w/problems

    realign the control unit in accordance with paragraph 4-7j. Also follow this procedure if the engine speed hunts. TM 5-6115-465-34 4-22 that is 1770 RPM to 1860 RPM 58 hz to 62 hz in the video seems like it is to me,
  11. glassk

    M1101

    take two of those, seems the bolt on pintle makes the hooks a little short, just in case
  12. glassk

    MEP-004A & MEP-005A Parallel Cable Assembly

    Sorry about not knowing the models you have and steady typing, those cables 7 and 8 are the one you need for second load , looks like the settings in relay boxes are the voltage and frequency setting s for the permissive relay, so being able to adjust the two , the oncoming to the online...
  13. glassk

    Lighting sets for army airfield runways and helicopters

    department of the army technical bulletin lighting sets for army airfield runways and helicopters
  14. glassk

    Can you identify this component of a Generator trailer?

    http://hosted.comm100.com/KnowledgeBase/What-Is-A-Demil-Code-_A18.aspx?id=18&siteid=157318 A demil code is a code assigned by the Federal Government that identifies the level of demilitarization required. Demilitarization refers to the reutilization of property previously used in the...
  15. glassk

    MEP-004A & MEP-005A Parallel Cable Assembly

    Paralleling of precise generator sets requires that paralleling cables be installed and the shorting plug in the lower paralleling receptacle of each generator set be removed. Paralleling of utility generator sets requires that the shorting plugs be installed on all sets. WARNING I have the...
  16. glassk

    MEP-004A & MEP-005A Parallel Cable Assembly

    It's for gen 1 and gen2 I think, into switch box, they have item 7 and 8 to the one cable maybe it's for the precise set and special relay box, the operators section on it in the 14 manual I think the ones with electrical speed control can sense a load problem and start the second unit when...
  17. glassk

    M1101

    It's like I saw in a Post on here, How big is a Rock,...? I have bought a lot of things, Paid $990 plus fees about $1100 gas and .lunch and all going to SC to get it, looked at and started taking notice of what I thought they would close at and what they sold for, , one with two low hour...
  18. glassk

    MEP-004A & MEP-005A Parallel Cable Assembly

    http://www.parttarget.com/6150-01-291-2306_6150012912306_13226E7718-1.html http://www.parttarget.com/6150-01-296-5751_6150012965751_13226E7718-2.html took those and put in webflis for nsn's bet that box on Dales trailer is the relay box, Figure 5-28. 50/60 Hz Precise Relay Assembly...