Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!
Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.
You do NOT need the MOV update. That only applies to the MEP-802A & MEP-803A.
From my limited experience with the Governor Controller module you need the following signal to it in order for it to send power to the mechanical actuator on the engine while cranking.
1) 24 volts DC power across...
Yes, the MOV is very inexpensive. I just received a batch of them.
If you want I can ship you one with the wire lugs already on it.
PM me if interested.
The one I provide with MEP-802A & MEP-803A Fuse Mod Kits is PN: MOV-14D151K
---> MOV
The addition of the MOV is an enhancement that I came up with to help protect the A1 AC Voltage Regulator.
The Fuse Mod itself only protects the Quad winding in the gen head from getting damaged if the bridge...
Just a thought. You may want to remove the droop adjust plug and manually move the FSS from Run position to the Stop position and see if the end of the rack quickly moves all the way to the stop position (left) or if it slowly moves to the stop position due to a possibly sticky injection pump.
I just un-stuck a pair of 802 IP (Metering Pumps). Both were stuck with the return spring compressed.
I tried soaking them assembled in Berryman Carb/Parts cleaner. Still stuck. I them removed the top, springs and parts from each.
Like this..
I then soaked in the same solution for another 3...
How is the slip ring assembly removed from a 8MR3005CA Alternator?
I need to replace the diode assembly(s) and need to get to rotor out of the housing to do so.
This....
Your actuator isn't lifting off the magnet when you engage the starter!
By staying on the magnet fuel is prevented from being sent from the new metering pump to the injector.
It's cranking kind of slow. Maybe not enough voltage to cause the governor controller to pop the actuator off the...
The conversion involves removing the inverter, PMA and SLC100 Governor Controller module.
Relocating the J7 connector to make room for the gen head
Installing the new gen head and installing the conversion kit.
The kit includes:
New Governor Controller module to maintain 3,600 RPM for 60 Hz...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.