  1. K

    MEP831A - Overvoltage Fault

    The problem is the Overvoltage fault the Fault monitor is reporting is causing the K12 Fault Relay to turn on which kills power to the GC. No power at F-G. K12 Is the leftmost relay behind the gauges. If S1 is in Run and the led inside K12 is on while its running it indicates the fault monitor...
  2. K

    MEP831A - Overvoltage Fault

    Kurt here... No power at the outlet may be due to the tiny circuit breaker on the GFCI is tripped. Also the GFCI contacts can be flakey. Sometimes I have to tap the Reset button mine to get juice to the outlet. If the meter shows AC voltage the outlet should get power assuming breaker and...
  3. K

    Mep804A issues.... and single phase?

    Test the VR per the -24 TM and post up the results of each test step. The 804 was made with two different VR systems. Libby and TRC. Be sure to use the correct test procedure in the TM.
  4. K

    802a no power at lugs

    A bit of info what keeps K1 closed. The CR3, S5-2, S5-3, K8-OL, K8-SC, K1-11, K1-12 path to ground is the latching path that keeps K1 closed when you release S5. When you put S5 in OPEN it breaks this path, K1 opens as well as the K1-11, K1-12 switch in K1. The other side of the K1 coils gets...
  5. K

    802a no power at lugs

    Here is the circuit from the -24 TM when you lift and HOLD the contactor switch UP. The GREEN circuit path should have 0 volts on it and the Pink-ish should have 24 volts DC on it. This applies 24 volts to the coil in K1. K1-X get 24 volts and 0 volts to K1-Y. The causes the contactor K1 to...
  6. K

    Generator exercise??

    That method is for cheapo gensets (portable big box generators such as like Generac, Coleman, TroyBilt, Homelite, etc) that have lost their residual magnetism in the rotor. They have no means of building up the residual magnetism to get the AC generation working enough for their voltage...
  7. K

    802a stops suddenly video- suggestions moving forward

    The problem could be trash in the tank getting sucked up by the pickup tube or anything from the pickup tube all the way thru to the fuel return line. Just work your way thru the fuel system either cracking fittings or disconnecting fittings and see if there is reasonable fuel flow from the...
  8. K

    Mep802a starts then shuts off

    Here is the path of the START signal from S1 to the K2 starter relay. There should be about 24 volts all along this path when S1 is in START. S1-7------TB5-14------K12-8---K12-2-----K16-9---K16-6-------S7-1---S7-2-----TB5-20--------J6-20---P6-20-----K2-X2
  9. K

    Mep802a starts then shuts off

    Figuring out why the starter isn't engaging will require tracing the START signal from S1 to the starter relay coil K2. I'll post up a sequence of measurements to check that path.
  10. K

    Mep802a starts then shuts off

    When testing resistors and other 2 leaded components one of the leads needs to be disconnected from the circuit before measuring. If left connected other components in the circuit can cause the readings to be way off.
  11. K

    MEP 831A Governor Control Issue? (video)

    My understanding is that the spherical nut on the bottom of the rod should stay in contact with the black throttle arm.
  12. K

    MEP 831A Governor Control Issue? (video)

    I would suggest adjusting the rod length per the TM and see if you can achieve 5/16" gap at no load and have it remain running. Maybe a tiny bit wider if the magnet grabs it.
  13. K

    Mep005 no power

    I'm wan't necessarily thinking it was the A5. Just wanted to provide the testing info should you or Guy think A5 could be the problem. I'm not an expert on the 005 like @Guyfang is. You can use 120 Volts 60Hz (power from house AC outlet) instead of 400 Hz to supply power to terminals 18 & 22...
  14. K

    MEP 831A Governor Control Issue? (video)

    With my A5 in there the actuator will not lift off the magnet until you put S1 in START. The moment S1 goes into the START position my A5 sends a pulse to the actuator to lift the actuator off the magnet. If this is not happening, then it would appear the magnet strength may be set too high...
  15. K

    Mep005 no power

    Here is some info on the A5 Card that may be of some help in testing the A5 card. Schematic of the A5 Card in the TM test setup. R3 is a 2.7K ohm resistor. Test Procedure using above test setup Component layout of the A5 card
  16. K

    MEP-804A No AC power when start switch is released.

    Jumpering those two terminals is connecting the RUN circuit to the START circuit. So, when S1 is in any run position the START circuit is continually energized. When this happens the field Flashing function is also continually on supplying flashing voltage to the exciter causing the generator...
  17. K

    400A Manual Transfer switch?

    Would require a mechanical interlock if they are allowed in your area. Locks out utility service when generator breaker is closed.
  18. K

    MEP802A not starting . Notice anything major in video

    The tab they are pressed into should rotate about 180 degrees
  19. K

    804A power transfer issue

    Are you handy with a hand held meter? Are any Fault Lamps illuminated after starting it?