Search results

  1. 155mm

    Safest way to uses a MEP 804b as a backup generator

    This is the switch Chris was refering to, you can see the load (house) is the center poles, the bottom post (power company), top posts (generator). With this switch there is no way to get power from the genny to line, unless there is major ground issues. If you have not read this thread, would...
  2. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    I didnt find any way to get in the k8 relay, its a throw away.
  3. 155mm

    MEP-804A single phase 120/240 conversion issue

    What about a phase converter? like this https://youtu.be/ZqnfLHhuuUQ
  4. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Since it ran for a couple hours, I would check the flame sensor for correct adjustment, then clean the filter. I sure might be interested in a brass adapter to have as a spare. I would look at the rectifier to see that it has all 4 wires, the 2 wires on the back of the hour meter have plastic...
  5. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Somehow I missed this Issac, I am assuming you are talking about an H81?
  6. 155mm

    Generator spacer dimensions

    Alrighty, I had a bag of them and put them in a safe spot, well now i cant find the safe spot.
  7. 155mm

    Generator spacer dimensions

    Can someone get me the dimension for the generator spacer on a 60 amp? PN 12338186-20 nsn 5310-01-292-5354 Item 12 in photo
  8. 155mm

    MEP-803A Starting kVa capacity

    Single phase jenny's are the easiest way to go, if he needs more than the 10kw to start up something, then the 15 would be 'the way to go' due to necessity. I have only found a couple older AC units that are not compatible with 208, but they were in the scrap metal. Even our new Kenmore dryer is...
  9. 155mm

    Winter Storm Preps

    oh boy, i have laughed myself silly.
  10. 155mm

    Winter Storm Preps

    How did you come up with this ratio of K1 to diesel? Sounds like a good ratio to me, esp since k1 is $7/gal down here. Best thing I know of to thin diesel though.
  11. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    I had a buddy build a couple for his h140’s, if someone can get dimensions to see if they are the same part that would be very helpful
  12. 155mm

    Block Heating ... How long?

    On my smaller diesels, duramax, about an hour is good. On my big truck, single turbo Cat, all night. I tried 1 hour on the big motor, then 2 hours and it would still take 30 minutes idle and 2 miles to warm the heater up at 15-25*F. All night plugged in, 30 minutes idle, and it was warm. I have...
  13. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Here is what I did, just a cut, solder, shrink.
  14. 155mm

    Standard HMMWV antenna for cb antenna?

    How many watts can be pushed thru this setup?
  15. 155mm

    Standard HMMWV antenna for cb antenna?

    Is there a mod to get the 6707 down to the 27mhz, I thought it only went as low a 30mhz. or is it just an adjusting the antenea height to get the SWR down?
  16. 155mm

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    item 2 is the fuel cut off/throttle control. there is a bolt and a funny spring that holds that in the IP. Also that has its own oil, so if you take off that plate, make sure to refill the oil. If I remember that is in the instructions for IP replacement. If you dont have to dinker with...
  17. 155mm

    MEP-804A cranks but no start, suspect solenoid on side of injection pump

    I would start here TM 9-6115-643-24, pg 2-304 magnetic pickup. Follow directions exactly. Update please if that doesnt fix it
  18. 155mm

    Fixing the Model H82/83 Engineered Air Systems Heaters

    Might run the exhaust temp lower to start since its new to you. In case there are hiccups to overcome
  19. 155mm

    Fixing the Model H82/83 Engineered Air Systems Heaters

    For maximum heat, all the way up was not it for mine. I run mine 1 tick mark down from the last numbers. The unit is noisey without the flame screens and side door removed. Hour meter only functions in the heat position if connected, if hour meter doesnt function in heat mode, check the...
  20. 155mm

    Buying a HEMTT across the country

    So the way I do it, I plan/budget to have the truck shipped, then go get it and drive it home myself. If it breaks down, you call a trucking company, have them load up and take it the rest of the way, then you get on a train/plane and go home. If/when you make it home, then you saved yourself...