• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. K

    MEP-002a LED Light Flicker

    Also check the probes to see if they are 1X, 10X or something else. A 10X probe only passes 10% of the voltage to the scopes input. Some scopes automatically detect which X factor the probes are and auto adjust the scaling accordingly. Other scopes don't automatically detect the probe type and...
  2. K

    2X MEP-802A Dead on Arrival... won't crank... Crank Relays Dead

    https://www.steelsoldiers.com/showthread.php?175090-MEP-803A-will-not-turn-on/page4 There is an explanation of how the Interruptor works. It one of the last posts.
  3. K

    MEP 803A will not turn on?

    The convenience outlet are not wired into K1. They are fed separately. Here is a description of the latching circuit I did a while back... It's a latching circuit created by K1, S5, CR3 & K8. After the engine starts and oil pressure is up K20 closes and K1 terminal X has 24 volts supplied...
  4. K

    Opinions on MEP-831A

    From my GLA experience you have to have items on your Watchlist in order to see what they've actually sold for. Need to go to Closed Watchlist on GLA to see what they've sold for. I followed a bunch of them coming out of GA recently. They sold for about $600-700 on average on GovPlanet. 37 of...
  5. K

    MEP-831A SLC100 Governor Controller Replacement Prototype

    Marty, I appreciate the offer. The schematic is finalized and I already generate the needed Gerber files to get them fab'd by a PWB fab house. Have had great results with the house I use. Quick turn times, great quality and reasonable prices. If I can help you with your 831 woes just let me...
  6. K

    MEP-831A Does not produce 240 volts?

    If the meter reads 120 then the switch is in the wrong position. If you haven't already you ought to download a copy of TM 9-6115-639-13&P. It covers that and everything else about running the 831A. https://www.steelsoldiers.com/showthread.php?155865-Manuals-for-the-MEP-831A
  7. K

    MEP-831A Does not produce 240 volts?

    Is the toggle switch on the top of the inverter set to 240? Do NOT change the setting with the set running!
  8. K

    MEP-831A SLC100 Governor Controller Replacement Prototype

    Ted - Thank you for the improvement suggestion. :roll: I too noticed the font was a bit small too. I revised the design and incorporated a larger font size for the terminal lettering. Those new PWB's just arrived this weekend. At the same time I ordered all the parts to build the next batch...
  9. K

    Anyone along the East Coast without power right now?

    Utility power still on here in Pepperell, MA
  10. K

    My MEP-803a genset has antifreeze leaking inside the cabinet

    See post #10 for a pic of my solution for my leaking cap. https://www.steelsoldiers.com/showthread.php?162006-MEP-803A-Finally-scored-one-and-had-a-question&highlight=bolt
  11. K

    My MEP-803a genset has antifreeze leaking inside the cabinet

    My 802 had a leak in that area when I got it. There was a rubber cap on an unused nipple on the water pump. It had dried, cracked and was weeping. Others have had the same issue with the rubber caps leaking. Could be the cap leaking if it isn't the plug pointed out in the post above.
  12. K

    Winter Storm Preps

    Nice! Have been looking for a set with the block heater to come to auction nearby. Hopefully this storm won't clobber "us" too hard. 12-18 expected here. Have my sets ready to run, 13 Kw battery bank charged and 2 drums of treated diesel at the ready. Bring it on!
  13. K

    My Mep-803a standby generator project

    Looks to be the fuel strainer from the fill tube. The view is of the bottom end of it.
  14. K

    Going through auction 803a

    That's the one.
  15. K

    My Mep-803a standby generator project

    windyhill Looks like you got a nice genset there! Congrats. The G7200 works well. Use it on my 3 sets.
  16. K

    803a Battery charge gauge ?

    All is normal. It will show discharging when on prime or preheat since the engine isn't running and you're drawing current from the batteries then. Discharging. Once you start it the batteries start to re-charge. Charging. After a short time of running the batteries are fully charged and the...
  17. K

    New member & 803a owner

    Nice looking genset and trailer! Make sure it has the "Fuse Mod". See https://www.steelsoldiers.com/showthread.php?169771-Military-MEP-generator-reset-information For the link to the document containing the Fuse Mod info.
  18. K

    MEP-003 recovery and adventure

    Normally for the frequency to be all over the place the engine RPM would have to be wildly changing. I assume it's steady. The output waveform from the generator may be distorted and causing the electricians meter reading to jump around. I'd suggest using an oscilloscope and looking at the...
  19. K

    mep831 inverter

    I just check my two 831's and the inverter housing is bonded to the generator skid & frame. It wouldn't make sense for the inverter housing to float since this could create a shock hazard to anyone servicing the set. Current should not be flowing between the gensets frame and the inverter...
  20. K

    803a vs 813, what’s the difference

    The key thing to know is... MEP-803A = 60 Hz power output MEP-813A = 400 Hz power output