So when I purchased the unit they told me all I needed to do was replaced some fuel lines and fuel pumps and new batteries. So I got them replaced and hooked up the batteries and went to flick the switch and nothing happened (by that, what do you mean, "nothing"? Do the panel lights work? Will the Fault Indicator light up when you turn the S2, (start switch) to the run position?) I tried flicking the battle short switch (when you turn on the S7, (Battle Short) will the DS7, (Battle short light) come on?) to get the fuel pumps to turn on (unhook one of the electric fuel pumps. Measure from the J5, (electric fuel pump connector) for 24 VDC, with the S2 in run and the S7 in the up position. Measure from pin to ground. What you get?) and nothing.I put my voltage meter to the switches power is going in and out of them. But it’s not getting to all the parts I tested the starter and it works. (good that the starter works, but its rarely the problem)
I am thinking it is the relay assy special 70-1053 be more Pacific Dc relat assy 69-768 but not knowing what dose what thats just a guess.
Dont jump ahead.
1. Have you downloaded all the TM's for your set? Have you read the operators TM, to learn what is what? How to properly start the set? They are here in the TM forum if not.
2. Tell us what it will and will not do. You are a bit skimpy on on that. It sounds like it will not start, but by not start, do you mean the set will turn over, and not start and run? Or do you mean the starter will not engage?
3. Are the battery's fully charged?
4. are any idiot lights on?
5. Are you sure nothing else is missing from the set?
6. "New fuel pump"? What fuel pump? The electric fuel pumps? The Injector Pump?
Answer my questions. It helps find a place to start. Are there any wires not connected? Or C-Plugs, (canon plugs) not hooked up or loose? The only wires not used on the set are 2 on the left front side, by the thermostat housing.