Ronmar
Well-known member
- 3,845
- 7,474
- 113
- Location
- Port angeles wa
Exactly what jump are you referring to? Because of this very confusion is why I only recommend “jumping” after I am positive the normal power is not available. Incorrect or unnecessary Jumping is how shit gets burnt up…
Gave you info on places to look and you never responded…
one last try:
Do you have 24v to pin 30 of relay K19?
if not, it comes from CB 79 in the panel, find out why.
if you do, insert a 5 pin relay and go see if you have 24v on the start solenoid on the governor. Wire labeled TL28 If not, find the break between solenoid TL28 and K19. If low voltage, find the bad/weak connection limiting the voltage under load.
If you have power on TL28, check the opposite solenoid terminal for a low resistance path to ground. Then check solenoid coil resistance(dont recall the spec).
like I described to chucky you can remove both solenoid terminal connections and connect 24v and ground to the solenoid terminals to power it.
lost track of how much burnt up crap and secondary issues I have seen from people hacking/bypassing installed wiring…
good luck…
Gave you info on places to look and you never responded…
one last try:
Do you have 24v to pin 30 of relay K19?
if not, it comes from CB 79 in the panel, find out why.
if you do, insert a 5 pin relay and go see if you have 24v on the start solenoid on the governor. Wire labeled TL28 If not, find the break between solenoid TL28 and K19. If low voltage, find the bad/weak connection limiting the voltage under load.
If you have power on TL28, check the opposite solenoid terminal for a low resistance path to ground. Then check solenoid coil resistance(dont recall the spec).
like I described to chucky you can remove both solenoid terminal connections and connect 24v and ground to the solenoid terminals to power it.
lost track of how much burnt up crap and secondary issues I have seen from people hacking/bypassing installed wiring…
good luck…