• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    lick your fingers and grab the output terminals? ahaha, i kid, i kid. https://www.steelsoldiers.com/attachment.php?attachmentid=477423&d=1392150685 that link should be the TM
  2. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    black box with 2 big wires on the intake air side floor
  3. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Did you remove the whole burner assy? or just the cover? If you removed the burner assy, check and double check the spark gap and alignment to the injector. When you say fuel but no spark, when you view the burner chamber thru the peep sight, you have no blue spark while in vent mode?
  4. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Check the flame sensor for proper alignment. The sensor is held in place with a rubber tube, tube gets hot, then cools down and pulls the sensor out of alignment. Not the greatest enginerding , had 1 heater that had to be re-engineered with plastic ties to keep it in place.
  5. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    What is it not doing? or what is it doing.
  6. 155mm

    M998 stalling at highway speeds

    My guess is the pickup in the tank or something in the tank sucking up against the pickup. If the new fuel filter, and the fuel pump test ok, nest easy test is in tank.
  7. 155mm

    Shipping costs

    I am 110% happy with every shipper I have used on UShip, they are just hardworking squirrels like us trying to get a nut, so if the rate seems cheap, kick them a little when they deliver. A 20 goes a long way with dirty old truck drivers.
  8. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Isaac, was this out of an army use heater that probably got psi washed? or was it from a long term storage, real 1 hour heater?
  9. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    its mounted on the inside, next to the switches. the only way i know is with a clamp over dmm that has amp and put it on max hold. then its just a process of clamping over each wire on the junction block to find the one that is pulling the amps. has that breaker been tripped alot of times...
  10. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    maybe you need to send me one of your k8 so we can verify your heater isnt eating them. is your hour meter disconnected? if not, unplug it and the rectifier
  11. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    There is such thing as bad new parts, and these are NOS so there is a higher chance of getting nonfunctional parts. If you have the funds available, I would order another new K8, but I would send the seller a pm letting him know that the first one was bad. He might offer a better deal on the...
  12. 155mm

    Safest way to uses a MEP 804b as a backup generator

    I have had no issues running 208 to a 240v water well, BUT it is a gamble. Our water well repair shop says the well motors are rated 240 +/- 10% for warranty issues, so 208 is outside the 10% but just a little bit for warranty. How would warranty know the difference between a brown out and 208...
  13. 155mm

    Safest way to uses a MEP 804b as a backup generator

    This is the switch Chris was refering to, you can see the load (house) is the center poles, the bottom post (power company), top posts (generator). With this switch there is no way to get power from the genny to line, unless there is major ground issues. If you have not read this thread, would...
  14. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    I didnt find any way to get in the k8 relay, its a throw away.
  15. 155mm

    MEP-804A single phase 120/240 conversion issue

    What about a phase converter? like this https://youtu.be/ZqnfLHhuuUQ
  16. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Since it ran for a couple hours, I would check the flame sensor for correct adjustment, then clean the filter. I sure might be interested in a brass adapter to have as a spare. I would look at the rectifier to see that it has all 4 wires, the 2 wires on the back of the hour meter have plastic...
  17. 155mm

    Its cold outside lets talk Heaters, H81, H82, H83, etc.

    Somehow I missed this Issac, I am assuming you are talking about an H81?
  18. 155mm

    Generator spacer dimensions

    Alrighty, I had a bag of them and put them in a safe spot, well now i cant find the safe spot.
  19. 155mm

    Generator spacer dimensions

    Can someone get me the dimension for the generator spacer on a 60 amp? PN 12338186-20 nsn 5310-01-292-5354 Item 12 in photo
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks