Correct, I do offer a replacement for the A1 Voltage Regulator. Yes it works even if the Quad Winding is bad.
Failure of the Voltage Regulator due to its internal diode bridge shorting out is linked to when the set is started. So it may have failed just as you started it recently. Voltage...
Gary,
The resistance spec for the MEP-803A Quad winding is only 0.9053 to 1.224 ohms. When measured with a common DMM it's will appear to be be shorted. Common DMM's don't measure really low resistances well.
Based on your description of the "Fuse Mod" fuse repeatedly blowing generally...
K4 is the Overvoltage Relay. It's actually one of the black box's bolted down behind the control panel. It's the first black box to the left of S14.
Not that I'm aware of. Sometimes you have to piece the info together using the -24 and -24P.
There is a table in the -24 in the schematics that...
Here is an updated picture with the function labelled on top of each relay.
S14 is the Frequency Trip Switch. Responsible for sensing when engine RPM > 900 RPM. Causes K16 to open and close.
K12 is the Fault relay. It activates if the sets Fault Monitor detects a fault. Causes set to shut...
I believe Guy's post mentioning "Plastic Relay" was referring to the relay common to the row of relays behind the control panel.
Specifically K12, K15, K16, K19 & K20
They are all KUP-14D15-24 Potter & Brumfield relays
S14 is the oddball Frequency Trip Switch (of which you have 2 heading your way)
To my knowledge there were two different manufacturers of the Frequency Switch S14. The internals look slightly different but do the same function.
The Aux Fuel Pump operation does not rely on the fuel level sender for the fuel gauge. It is controlled by a separate float switch in the fuel tank.
Simple, just buy a bridge rectifier rated at 400 PRV and use 3 out of 4 of its terminals. Use the + and the two AC input terminals. Plus terminal to L2 and two AC terminals to the other inputs.
MEP-802A & MEP-803A Frequency Trip Switch - S14
Replaces 5930-01-396-2940, SPS-100-88-21091, 88-21091
· Direct replacement Frequency Trip Relay for S14 for the MEP-802A & MEP-803A
I personally assemble each of the S14 Frequency Trip Switch's. Once built each S14 is installed in my MEP-802A...
Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!