m109a2, you were also one of the lucky ones, my inlaws lived just east of Lake Charles when Rita hit, they lost part of the roof off their house (blue tarp for 4 months), were running low on Propane before the storm hit and ran out 2 days after it hit (had ordered a refill 2 weeks before, but...
Year before last we had a similar thanksgiving day incident, power went off during thanksgiving dinner for no reason for about 15-20 minutes. If it had lasted longer or happened a couple of hours earlier we would have switched over to generator power, as it was we had plenty of natural light...
Crabbie just try that for a while in Louisiana in the summer the week after a hurricane hits when it is 98 degrees outside and 90+ percent humidity, and add to that a wife that has a medical condition where she has to avoid getting over heated.
Just a couple of notes here, the OP is located in Texas, there have been issues reported with using the MEP-002a / 003a with ASK in hot climates. Another thing to keep in mind when it comes to the topic of replacement parts, in general you will never buy replacement parts for a generator during...
First of all, unless you have a lot of other electric loads, you are shopping WAY too big, and bigger is not better when it comes to diesel generators (look up wet stacking). I have bought 6 or 7 generators (along with other equipment) off GL over the last decade, of those generators only one...
I would say the question here is a matter of driving a ground rod or not. This is a topic of some debate on portable generators, as the NEC generally calls for grounding, but OSHA changed its standard to being ungrounded (under certain conditions) about 5 years ago...
The boards are not the same, or may not be, the original MEP-002a board will burn out if used in a MEP-003a, but a MEP-003a board can be used in MEP-002a. It also appear that the 10KW 400 hz version of the board may be able to be used in a MEP-002a
The external fuel fitting is an AN fitting but it will mate with commercial JIC fittings, off hand I think it is a -4 or -5 size, as I recall MEP-002 uses -5 and MEP-016b uses -4, but I would not bet on that.
When you say screw valve thing on the pump head, are you referring to the knurled knob there? If so that is the injection pump stability control knob. As to the rest with voltages, it would help if you told us exactly what you have that you are trying to power
Part of the problem with grounding is it is NOT a simple issue, and depends on a lot of details for how you do it and still be code compliant even if the basic concept is fairly straight forward, in addition the NEC code as it relates to generator installation has been extensively revised in the...
Wow this thread has certainly taken a nose dive in the last few hours,
alphamale: As others have said it seems you lack a basic understanding of household wiring, and I don't mean for this post to complete fix that, but perhaps it will get you on the right path. Household power in the U.S. is...