Search results

  1. I

    How much power (kw's) do I need for my home?

    We have exchanged a few messages online over the years, but as far as I know we have not met in person
  2. I

    How much power (kw's) do I need for my home?

    m109a2, you were also one of the lucky ones, my inlaws lived just east of Lake Charles when Rita hit, they lost part of the roof off their house (blue tarp for 4 months), were running low on Propane before the storm hit and ran out 2 days after it hit (had ordered a refill 2 weeks before, but...
  3. I

    Which Diesel Generator Would You Recommend or NOT Recommend?????

    Year before last we had a similar thanksgiving day incident, power went off during thanksgiving dinner for no reason for about 15-20 minutes. If it had lasted longer or happened a couple of hours earlier we would have switched over to generator power, as it was we had plenty of natural light...
  4. I

    Which Diesel Generator Would You Recommend or NOT Recommend?????

    Crabbie just try that for a while in Louisiana in the summer the week after a hurricane hits when it is 98 degrees outside and 90+ percent humidity, and add to that a wife that has a medical condition where she has to avoid getting over heated.
  5. I

    Which Diesel Generator Would You Recommend or NOT Recommend?????

    Just a couple of notes here, the OP is located in Texas, there have been issues reported with using the MEP-002a / 003a with ASK in hot climates. Another thing to keep in mind when it comes to the topic of replacement parts, in general you will never buy replacement parts for a generator during...
  6. I

    MEP003 CB2 DC control breaker

    On the topic of the slats, be aware they operate by a cylinder of expanding wax, so do not try to disassemble and clean it out.
  7. I

    Which Diesel Generator Would You Recommend or NOT Recommend?????

    First of all, unless you have a lot of other electric loads, you are shopping WAY too big, and bigger is not better when it comes to diesel generators (look up wet stacking). I have bought 6 or 7 generators (along with other equipment) off GL over the last decade, of those generators only one...
  8. I

    MEP 120V Output, Balanced vs. Unbalanced

    I would say the question here is a matter of driving a ground rod or not. This is a topic of some debate on portable generators, as the NEC generally calls for grounding, but OSHA changed its standard to being ungrounded (under certain conditions) about 5 years ago...
  9. I

    MEP 003A Unstable Voltage

    The boards are not the same, or may not be, the original MEP-002a board will burn out if used in a MEP-003a, but a MEP-003a board can be used in MEP-002a. It also appear that the 10KW 400 hz version of the board may be able to be used in a MEP-002a
  10. I

    MEP 003A Unstable Voltage

    I had a similar intermittent problem on my MEP-002a, ended up swapping out the AVR board since then it has been rock solid.
  11. I

    Are 3kW MEP-016 Gen Heads Interchangeable?

    I am fairly sure they have the same part number if that helps
  12. I

    MEP-016B Generator Startup

    Air filter is a Donaldson part # I have a couple, but am on vacation now, will try to post it when I get home in a few days.
  13. I

    Mep002/3 spin on oil filter

    I bought one of Speddmons kits, it is a great quality bit of machining.
  14. I

    MEP-016B Generator Startup

    The external fuel fitting is an AN fitting but it will mate with commercial JIC fittings, off hand I think it is a -4 or -5 size, as I recall MEP-002 uses -5 and MEP-016b uses -4, but I would not bet on that.
  15. I

    MEP003A Starts Hard, Black smoke, runs 10 seconds, white smoke, then Dies....Ideas?

    Sounds like something in the injection pump, you might try flow timing it and see if it has the wrong timing button, or worse.
  16. I

    MEP-016b vs MEP-831a

    Why not also consider the MEP-016D and MEP-016E?
  17. I

    MEP 004A RPMs too low fuel pressure problem - help!

    When you say screw valve thing on the pump head, are you referring to the knurled knob there? If so that is the injection pump stability control knob. As to the rest with voltages, it would help if you told us exactly what you have that you are trying to power
  18. I

    Pre Purchase MEP 710a questions

    Part of the problem with grounding is it is NOT a simple issue, and depends on a lot of details for how you do it and still be code compliant even if the basic concept is fairly straight forward, in addition the NEC code as it relates to generator installation has been extensively revised in the...
  19. I

    Pre Purchase MEP 710a questions

    Wow this thread has certainly taken a nose dive in the last few hours, alphamale: As others have said it seems you lack a basic understanding of household wiring, and I don't mean for this post to complete fix that, but perhaps it will get you on the right path. Household power in the U.S. is...
  20. I

    Pre Purchase MEP 710a questions

    Ok, lets take a step back and ask, what are you wanting to do with this generator, and how?