• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. I

    need help with starter for my 89 3 kw 24v generator

    Ether is a bit like Russian roulette when used on a diesel engine, you might get away with it, if it is a very short squirt, but it is best to avoid if you can. Ike p.s. I too think you have air in your fuel lines
  2. I

    Repairing a ASK kit

    I don't know about the MEP-002 ASK, but the MEP-701 uses what I think is Owen 703 fiberboard insulation, held in with a perforated thin metal screen.
  3. I

    MEP 003a back together...but...

    You may have an output lead connected wrong, double check, also post numbers for L1-L2, L1-L0, etc. depending on voltage mode, mostly we would be looking at the right ratio here not the voltage. If the ratio is right it is probably your voltage regulator or transistors. Ike
  4. I

    MEP-701A Replacement Supplies

    For the Yanmar you need to search on MEP-016E, for the Onan Air filters and fuel filters are hard to find as they are not standard parts, but can sometimes be found on ebay, etc. Air filter for the Onan powered MEP-701a is Nelson 70301-N Oil Filter is Napa 1378 (numerous crosses here as it is...
  5. I

    HZ question...

    The general suggestion in the commercial generator world is when dealing with a mechanical governor generator is to set it so it droops under constant load to 60 hz, often this will mean setting the no load speed to 62 Hz, and allow for drop to 58 hz when sudden load is applied
  6. I

    HZ question...

    I am fairly sure all of Canada is now 60Hz (I think the last legacy odd frequency system in Canada was reitred within the last decade though). Ike
  7. I

    HZ question...

    These days most digital clocks have in internal quartz crystal reference and don't really care about frequency for the most part most appliances don't care that much with the world market since most of Europe uses 50 Hz, the U.S. uses 60 HZ, then there is Japan where it is really crazy, the...
  8. I

    MEP-002A Question

    There is a message thread going on over on the Smokstak board on this very topic, it seems OSHA has issued new guidelines to NOT drive ground rods for portable generators. Of course if you have it connected to site wiring the NEC code may apply, which opens another whole can of worms over how...
  9. I

    MEP-002A Question

    I have heard of it happening with civilian Onan diesel J series engines when they were installed in applications where they would run many hours at low load, the DJB and DJC units were commonly installed for supplimental power in buses, fire trucks, and other diesel powered vehicles as well as a...
  10. I

    MEP-002A Question

    Ok, let me try to clear up a couple of things: It is fine to run this generator to power a saw or other power tools that you plan to run every few minutes, or even a few light bulbs, the problem with wet stacking comes in when you do this hour after hour, day after day. In general to avoid wet...
  11. I

    Hello evey one. New here ,and i just got a MEP-003A

    If it is a site that requires GL pickups to enter through the commercial truck gate, I suggest getting there very early, I had a pickup at Hooks a couple of years ago scheduled for about 8:30 am, I arrived early at 7 am and the big trucks were already lining up for the 8:00 am gate opening., I...
  12. I

    Quick solargizer question..?

    The current pulsetech 24V solar products (which are used by the military, have an NSN number, etc) are rated at 6 watts, their 12V units range from 3-25 watts, as a rule of thumb a well placed fixed solar panel will generator 5-6 times its peak output rating in watts per day from a typical mid...
  13. I

    Quick solargizer question..?

    Mike KK4AIF that is the way the traditional units work, the newer ones add that on top of a DC charging circuit, then revert to the mode you describe when the battery if fully charged.
  14. I

    Quick solargizer question..?

    Their newer models also charge (now sold as solar conditoiner/chargers) , it seems they have dropped the solargizer name from these now, but for a while these same models (look the same, and same part numbers) were being sold with the Solargizer name. The older models did "minimal" charging...
  15. I

    Hello evey one. New here ,and i just got a MEP-003A

    Welcome, and good luck, you may also want to look over in the GL section on advice and information regarding pick up at your specific location, things like access restrictions, which gate you must enter, etc..
  16. I

    MEP-701a Charging information

    Onemore comment on chaning the charging regulator, you will probably want an assortment of long flat head screwdrivers, it is possible to get one that will fit between the relays on the relay board and still be big enough to turn the screws on the 2 mounting screws once you lossen the nuts on...
  17. I

    MEP-003a Frequency Gauge

    If you find one let us know, this question comes up fairly often. As to your original meters, most of the time the problem is in the transducer not meter itself.
  18. I

    MEP-701a Charging information

    If your problem turns out to be the battery charging regulator there is a seller on ebay that has them for $100, note they are poorly listed, search on "libby regulator", I just had to replace mine due to over charging which killed my battery. If you do have to replace the regulator note the...
  19. I

    Looking at a mep-701a Or other

    My MEP-701a / 016b with the 1 cylinder Onan is connected for 120V only mode and will accept an instant near 3000 watt resistive load (a pair of 1500 watt cube heaters) with no noticeable strain the only difference that you see is a slight drop in frequency on the meter (down 1-2 HZ) and maybe a...
  20. I

    Calling all Generator Owners

    It is raining this morning, but I will try to get out to the back yard and see what the data plate on mine says soon. Ike ps checked, you were right, manual says empty weight 532 full 590
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks