  1. Daybreak

    Transfer switch MEP-803a

    Howdy, Generator Connection Choices Panel Interlock, Break out box, Generlink, Transconnect, DPDT switch
  2. Daybreak

    MEP-803A

    Go to the section of the Forums Steel Soldiers - Generators Also check out this thread. MEP-802A MEP-803A Filters and Parts
  3. Daybreak

    The infamous Well Nut info

    Howdy, GMG obviously read about it here. They picked some up, and are priced way above the going rate. All the links to the original well nut, and the brass bulk head fitting are right here. MEP-802A MEP-803A Filters and Parts go to the 2nd post, and follow the quick links. A3816 well nut...
  4. Daybreak

    source for upper radiator hose for MEP-803a

    Howdy, Member @Light in the Dark has sourced, fabbed, acquired, upper and lower MEP-802A/803A radiator hoses. He has a post up in the classified parts for sale section. MEP-802A/803A Preformed Coolant Hoses
  5. Daybreak

    MEP-802A MEP-803A Filters and Parts

    Howdy, A member has sourced, fab'd, upper and lower radiator hoses for the MEP-802A and MEP-803A MEP-802A/803A Upper and Lower Radiator hoses
  6. Daybreak

    Help contacting Green Mountain Generators

    Always post up your wants and wishes here first before going to green mountain.
  7. Daybreak

    MEP1040 fuel tank sender?

    Where did they say the fuel sender was crap? What garbage sensors?
  8. Daybreak

    MEP-803A has zero compression and lots of soot

    Howdy, I had a unit which was wet stacked. I removed the muffler, then used a shop vac to suck the ports as best as possible. I then removed the exhaust manifold. I scrapped and pressure washed it clean. I also washed out the muffler. Purple power and shaking it. Washed it out the best I could...
  9. Daybreak

    Low hour M803A Fuel leak, Cover suggestion

    Proper size 3.5mm or the 1/8" fuel return line does not need any clamps. All the fittings have hose barbs. The T fittings at the top all are hose barbed. Be very careful removing the old return lines. If you use a razor blades, start slowly slicing the outer part, until you can pull it off the...
  10. Daybreak

    Low hour M803A Fuel leak, Cover suggestion

    Howdy, NOTE: copper and diesel are not friendly. Start here in this thread. MEP-802A MEP-803A Filters and Parts | SteelSoldiers List all the different filter # and such. Since it is such a low hour unit, you should probably stay with a break-in oil for at least 100 hours. Change the oil, and...
  11. Daybreak

    Hannay Reel - Trailer Mounted MEP-803A

    eh? Where did you find out about the Graywacke NATO connector? maybe my post. I know how they work. I was advising you how the NATO plug works. They are tight. They are suppose to be. Pay attention now. ;) Type W 4C 6 AWG simply coiled up.
  12. Daybreak

    Hannay Reel - Trailer Mounted MEP-803A

    Howdy, Graywacke part# GEISLV-SR (tight fit, but it works) That is how the NATO slave port works. The center is sliced into 6-7 pieces which spread open when pushed on. AWG 4? that was a pretty penny. The Type W in AWG 6 is good to 87 amps. I have a 100ft of Type W AWG 6. :)
  13. Daybreak

    MEP-803A No Crank

    Howdy, I believe that connection is double nutted. Look and feel around the bottom, you will probably find the nut which vibrated off. Either way, good job tracking it down. :cool:
  14. Daybreak

    802a Hard Start - Thoughts?

    Howdy, It also could be not knowing how to start it properly. MEP-80x startup routine | SteelSoldiers Turn the S1 to prime and run, wait.... wait.... wait.... turn to start, and hold it there... oil pressure is up..ok release. Cold weather starting Turn the S1 to prime and run, wait...
  15. Daybreak

    genset loadbanks

    Howdy, I use a Essex A427 load bank. Works great single phase or 3 phase. (2) Acquired a Military surplus load bank | SteelSoldiers
  16. Daybreak

    MEP 1030, 1040 Models, Running Parallel

    Howdy, I do know some of the advanced base camp operations have proper control boxes which auto start units when more demand is needed. Maybe with 2-3 MEP-1070's and some MEP-1060's. But the camp micro-grid has lots more controlling pieces for it all to work. You need 2 x MEP-1040 to really be...
  17. Daybreak

    MEP 1030, 1040 Models, Running Parallel

    Howdy, I do not think you can mix sizes. Here.. :cool: (1) Generators in Parallel Operation | SteelSoldiers (1) AMMPS MEP-1030 5KW Generator | SteelSoldiers
  18. Daybreak

    Generator purchase advice

    Howdy, I am surprised Guy left out why the 004 and 005 are special. The genhead is a 12 wire unit. Because it can be re-wired to single phase. The MEP-804 and higher all have 10 wire units. You can't reconfigure to single phase.
  19. Daybreak

    AMMPS MEP-1040 10KW Generator List of Part Numbers

    Howdy, Technical manuals are here on Steel Soldiers. MEP-1040/1041 AMMPS 10KW 6115-01-561-7455 (3rd generation generator) TM 9-6115-750-10 - (Operation) TM 9-6115-750-24&P - (Parts)
  20. Daybreak

    AMMPS MEP-1030 5KW Generator List of Part Numbers

    Howdy, Technical manuals are here on Steel Soldiers. MEP-1030/1031 AMMPS 5KW 6115-01-561-7329 (3rd generation generator) TM 9-6115-749-10 - (Operation) TM 9-6115-749-24&P - (Parts)
Top